|
|
|
|
LEADER |
01000naa a22002652 4500 |
001 |
NLM244581908 |
003 |
DE-627 |
005 |
20231224135019.0 |
007 |
tu |
008 |
231224s2014 xx ||||| 00| ||eng c |
028 |
5 |
2 |
|a pubmed24n0815.xml
|
035 |
|
|
|a (DE-627)NLM244581908
|
035 |
|
|
|a (NLM)25506113
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Kim, H
|e verfasserin
|4 aut
|
245 |
1 |
2 |
|a A New Time Calibration Method for Switched-capacitor-array-based Waveform Samplers
|
264 |
|
1 |
|c 2014
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ohne Hilfsmittel zu benutzen
|b n
|2 rdamedia
|
338 |
|
|
|a Band
|b nc
|2 rdacarrier
|
500 |
|
|
|a Date Revised 20.11.2019
|
500 |
|
|
|a published: Print
|
500 |
|
|
|a Citation Status Publisher
|
520 |
|
|
|a We have developed a new time calibration method for the DRS4 waveform sampler that enables us to precisely measure the non-uniform sampling interval inherent in the switched-capacitor cells of the DRS4. The method uses the proportionality between the differential amplitude and sampling interval of adjacent switched-capacitor cells responding to a sawtooth-shape pulse. In the experiment, a sawtooth-shape pulse with a 40 ns period generated by a Tektronix AWG7102 is fed to a DRS4 evaluation board for calibrating the sampling intervals of all 1024 cells individually. The electronic time resolution of the DRS4 evaluation board with the new time calibration is measured to be ~2.4 ps RMS by using two simultaneous Gaussian pulses with 2.35 ns full-width at half-maximum and applying a Gaussian fit. The time resolution dependencies on the time difference with the new time calibration are measured and compared to results obtained by another method. The new method could be applicable for other switched-capacitor-array technology-based waveform samplers for precise time calibration
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a Switched-Capacitors
|
650 |
|
4 |
|a Time Calibration
|
650 |
|
4 |
|a Waveform Sampling
|
700 |
1 |
|
|a Chen, C-T
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Eclov, N
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Ronzhin, A
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Murat, P
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Ramberg, E
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Los, S
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Moses, W
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Choong, W-S
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Kao, C-M
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
|d 1987
|g 767(2014) vom: 11. Dez., Seite 67-74
|w (DE-627)NLM098171771
|x 0168-9002
|7 nnns
|
773 |
1 |
8 |
|g volume:767
|g year:2014
|g day:11
|g month:12
|g pages:67-74
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_350
|
951 |
|
|
|a AR
|
952 |
|
|
|d 767
|j 2014
|b 11
|c 12
|h 67-74
|