Ion channel probes for scanning ion conductance microscopy

The sensitivity and selectivity of ion channels provide an appealing opportunity for sensor development. Here, we describe ion channel probes (ICPs), which consist of multiple ion channels reconstituted into lipid bilayers suspended across the opening of perflourinated glass micropipets. When incorp...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1992. - 30(2014), 50 vom: 23. Dez., Seite 15351-5
1. Verfasser: Zhou, Yi (VerfasserIn)
Weitere Verfasser: Bright, Leonard K, Shi, Wenqing, Aspinwall, Craig A, Baker, Lane A
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2014
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't Ion Channels Lipid Bilayers
LEADER 01000naa a22002652 4500
001 NLM243806205
003 DE-627
005 20231224133320.0
007 cr uuu---uuuuu
008 231224s2014 xx |||||o 00| ||eng c
024 7 |a 10.1021/la504097f  |2 doi 
028 5 2 |a pubmed24n0812.xml 
035 |a (DE-627)NLM243806205 
035 |a (NLM)25425190 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Zhou, Yi  |e verfasserin  |4 aut 
245 1 0 |a Ion channel probes for scanning ion conductance microscopy 
264 1 |c 2014 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 13.08.2015 
500 |a Date Revised 13.11.2018 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a The sensitivity and selectivity of ion channels provide an appealing opportunity for sensor development. Here, we describe ion channel probes (ICPs), which consist of multiple ion channels reconstituted into lipid bilayers suspended across the opening of perflourinated glass micropipets. When incorporated with a scanning ion conductance microscope (SICM), ICPs displayed a distance-dependent current response that depended on the number of ion channels in the membrane. With distance-dependent current as feedback, probes were translated laterally, to demonstrate the possibility of imaging with ICPs. The ICP platform yields several potential advantages for SICM that will enable exciting opportunities for incorporation of chemical information into imaging and for high-resolution imaging 
650 4 |a Journal Article 
650 4 |a Research Support, N.I.H., Extramural 
650 4 |a Research Support, Non-U.S. Gov't 
650 7 |a Ion Channels  |2 NLM 
650 7 |a Lipid Bilayers  |2 NLM 
700 1 |a Bright, Leonard K  |e verfasserin  |4 aut 
700 1 |a Shi, Wenqing  |e verfasserin  |4 aut 
700 1 |a Aspinwall, Craig A  |e verfasserin  |4 aut 
700 1 |a Baker, Lane A  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1992  |g 30(2014), 50 vom: 23. Dez., Seite 15351-5  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnns 
773 1 8 |g volume:30  |g year:2014  |g number:50  |g day:23  |g month:12  |g pages:15351-5 
856 4 0 |u http://dx.doi.org/10.1021/la504097f  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_350 
912 |a GBV_ILN_721 
951 |a AR 
952 |d 30  |j 2014  |e 50  |b 23  |c 12  |h 15351-5