Coliform Sources and Mechanisms for Regrowth in Household Drinking Water in Limpopo, South Africa

Resource-limited communities throughout the developing world face significant environmental health problems related to the myriad of coliform sources within those communities. This study comprehensively investigated contamination sources and the biological and chemical mechanisms sustaining them in...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of environmental engineering (New York, N.Y.). - 1994. - 139(2013), 9 vom: 28. Sept., Seite 1152-1161
1. Verfasser: Mellor, Jonathan E (VerfasserIn)
Weitere Verfasser: Smith, James A, Samie, Amidou, Dillingham, Rebecca A
Format: Aufsatz
Sprache:English
Veröffentlicht: 2013
Zugriff auf das übergeordnete Werk:Journal of environmental engineering (New York, N.Y.)
Schlagworte:Journal Article Africa Bacteria Carbon Coliform Developing countries Drinking water Organic carbon Public health Rural areas mehr... South Africa Water quality
LEADER 01000caa a22002652 4500
001 NLM241612454
003 DE-627
005 20250217112031.0
007 tu
008 231224s2013 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0805.xml 
035 |a (DE-627)NLM241612454 
035 |a (NLM)25190902 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Mellor, Jonathan E  |e verfasserin  |4 aut 
245 1 0 |a Coliform Sources and Mechanisms for Regrowth in Household Drinking Water in Limpopo, South Africa 
264 1 |c 2013 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Revised 21.10.2021 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Resource-limited communities throughout the developing world face significant environmental health problems related to the myriad of coliform sources within those communities. This study comprehensively investigated contamination sources and the biological and chemical mechanisms sustaining them in two adjacent communities in rural Limpopo, South Africa. An 8-month study was conducted of household (n = 14) and source water quality, measurements of biofilm layers on the inside of household water storage containers and water transfer devices, and also hand-based coliforms and hand-washing effectiveness. A 7-day water container incubation experiment was also performed to determine the biological and chemical changes that occur in a household water storage container independent of human interference. Results indicate that household drinking water frequently becomes contaminated after collection but before consumption (197 versus 1,046 colony-forming units/100 mL; n = 266; p < 0.001). The most important contamination sources include biofilm layers on the inside of storage containers (1.85 ± 1.59 colony-forming units/cm2; n = 44), hands (5,097 ± 2,125 colony-forming units/hand; n = 48), and coliform regrowth resulting from high assimilable organic carbon (AOC) levels during storage. A maximum specific growth rate, μmax, of 0.072 ± 0.003 h-1 was determined for total coliform bacteria on AOC, and a high correlation between AOC concentrations and the growth potential of total coliform bacteria was observed. These results support the implementation of point-of-use water treatment and other interventions aimed at maintaining the safe water chain and preventing biological regrowth 
650 4 |a Journal Article 
650 4 |a Africa 
650 4 |a Bacteria 
650 4 |a Carbon 
650 4 |a Coliform 
650 4 |a Developing countries 
650 4 |a Drinking water 
650 4 |a Organic carbon 
650 4 |a Public health 
650 4 |a Rural areas 
650 4 |a South Africa 
650 4 |a Water quality 
700 1 |a Smith, James A  |e verfasserin  |4 aut 
700 1 |a Samie, Amidou  |e verfasserin  |4 aut 
700 1 |a Dillingham, Rebecca A  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of environmental engineering (New York, N.Y.)  |d 1994  |g 139(2013), 9 vom: 28. Sept., Seite 1152-1161  |w (DE-627)NLM098157280  |x 0733-9372  |7 nnns 
773 1 8 |g volume:139  |g year:2013  |g number:9  |g day:28  |g month:09  |g pages:1152-1161 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 139  |j 2013  |e 9  |b 28  |c 09  |h 1152-1161