Reverse osmosis and nanofiltration of biologically treated leachate

Experiments of nano-filtration (NF) and reverse osmosis (RO) were conducted to remove most pollutants from the biological treated leachate. For example, the purified permeate after reverse osmosis treatment with spiral membranes reached effluent water quality as follows: COD of 57 mg O2/l, BOD7 of 3...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Environmental technology. - 1993. - 35(2014), 17-20 vom: 21. Sept., Seite 2416-26
1. Verfasser: Kuusik, Aare (VerfasserIn)
Weitere Verfasser: Pachel, Karin, Kuusik, Argo, Loigu, Enn, Tang, Walter Z
Format: Aufsatz
Sprache:English
Veröffentlicht: 2014
Zugriff auf das übergeordnete Werk:Environmental technology
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Water Pollutants, Chemical
LEADER 01000naa a22002652 4500
001 NLM241184924
003 DE-627
005 20231224123713.0
007 tu
008 231224s2014 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0804.xml 
035 |a (DE-627)NLM241184924 
035 |a (NLM)25145196 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kuusik, Aare  |e verfasserin  |4 aut 
245 1 0 |a Reverse osmosis and nanofiltration of biologically treated leachate 
264 1 |c 2014 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 25.09.2014 
500 |a Date Revised 22.08.2014 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Experiments of nano-filtration (NF) and reverse osmosis (RO) were conducted to remove most pollutants from the biological treated leachate. For example, the purified permeate after reverse osmosis treatment with spiral membranes reached effluent water quality as follows: COD of 57 mg O2/l, BOD7 of 35 mg O2/l, and suspended solid of 1 mg/l which satisfies the discharge standards in Estonia. For both RO and NF, conductivity can be reduced by 91% from 6.06 to 0.371 mS/cm by RO and 99% from 200 to 1 mS/cm by NF. To test the service life of the RO spiral membranes, the process was able to reduce chemical oxygen demand (COD) and biological oxygen demand (BOD) of biologically treated leachate by 97.9% and 93.2% even after 328 and 586 hours, respectively. However, only 39.0% and 21.7% reductions of Ptot and Ntot were achieved. As a result, neither RO (spiral membranes process) nor NF was able to reduce the total nitrogen (TN) to the required discharge limit of 15 mg/l 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 7 |a Water Pollutants, Chemical  |2 NLM 
700 1 |a Pachel, Karin  |e verfasserin  |4 aut 
700 1 |a Kuusik, Argo  |e verfasserin  |4 aut 
700 1 |a Loigu, Enn  |e verfasserin  |4 aut 
700 1 |a Tang, Walter Z  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Environmental technology  |d 1993  |g 35(2014), 17-20 vom: 21. Sept., Seite 2416-26  |w (DE-627)NLM098202545  |x 1479-487X  |7 nnns 
773 1 8 |g volume:35  |g year:2014  |g number:17-20  |g day:21  |g month:09  |g pages:2416-26 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 35  |j 2014  |e 17-20  |b 21  |c 09  |h 2416-26