Sorption of Cr(III) and Cr(VI) to High and Low Pressure Synthetic Nano-Magnetite (Fe3O4)Particles

The binding of Cr(III) and Cr(VI) to synthetic nano-magnetie particles synthesized under open vessel conditions and a microwave assisted hydrothermal synthesis techniques was investigated. Batch studies showed that the binding of both the Cr(III) and Cr(VI) bound to the nano-materials in a pH depend...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Chemical engineering journal (Lausanne, Switzerland : 1996). - 1999. - 254(2014) vom: 15. Okt., Seite 171-180
1. Verfasser: Parsons, Jason G (VerfasserIn)
Weitere Verfasser: Hernandez, Jeffrey, Gonzalez, Christina M, Gardea-Torresdey, J L
Format: Aufsatz
Sprache:English
Veröffentlicht: 2014
Zugriff auf das übergeordnete Werk:Chemical engineering journal (Lausanne, Switzerland : 1996)
Schlagworte:Journal Article Chrmoium(III) Chromium(VI) XAS binding capacity nano-magnetite
LEADER 01000caa a22002652 4500
001 NLM240739213
003 DE-627
005 20250217083714.0
007 tu
008 231224s2014 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0802.xml 
035 |a (DE-627)NLM240739213 
035 |a (NLM)25097452 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Parsons, Jason G  |e verfasserin  |4 aut 
245 1 0 |a Sorption of Cr(III) and Cr(VI) to High and Low Pressure Synthetic Nano-Magnetite (Fe3O4)Particles 
264 1 |c 2014 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Revised 21.10.2021 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a The binding of Cr(III) and Cr(VI) to synthetic nano-magnetie particles synthesized under open vessel conditions and a microwave assisted hydrothermal synthesis techniques was investigated. Batch studies showed that the binding of both the Cr(III) and Cr(VI) bound to the nano-materials in a pH dependent manner. The Cr(III) maximized at binding at pH 4 and 100% binding. Similarly, the Cr(VI) ions showed a maximum binding of 100% at pH 4. The data from the time dependency studies showed for the most part the majority of the binding occurred within the first 5 minutes of contact with the nanomaterial and remained constant thereafter. In addition, the effects of the possible interferences were investigated which showed some effects on the binding of both Cr(III) and Cr(VI). However, the interferences never completely eliminated the chromium binding. Isotherm studies conducted at room temperature showed the microwave synthesized nanomaterials had a binding capacity of 1208 ± 43.9 mg/g and 555 ± 10.5 mg/g for Cr(VI) and Cr(III), respectively. However, the microwave assisted synthesized nanomaterials had capacities of 1705 ± 14.5 and 555± 10.5 mg/g for Cr(VI) and Cr(III), respectively. XANES studies showed the Cr(VI) was reduced to Cr(III), and the Cr(III) remained as Cr(III). In addition, the XANES studies indicated that the chromium remained coordinated in an octahedral arrangement of oxygen atoms 
650 4 |a Journal Article 
650 4 |a Chrmoium(III) 
650 4 |a Chromium(VI) 
650 4 |a XAS 
650 4 |a binding 
650 4 |a capacity 
650 4 |a nano-magnetite 
700 1 |a Hernandez, Jeffrey  |e verfasserin  |4 aut 
700 1 |a Gonzalez, Christina M  |e verfasserin  |4 aut 
700 1 |a Gardea-Torresdey, J L  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Chemical engineering journal (Lausanne, Switzerland : 1996)  |d 1999  |g 254(2014) vom: 15. Okt., Seite 171-180  |w (DE-627)NLM098273531  |x 1385-8947  |7 nnns 
773 1 8 |g volume:254  |g year:2014  |g day:15  |g month:10  |g pages:171-180 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 254  |j 2014  |b 15  |c 10  |h 171-180