Micromachined PIN-PMN-PT crystal composite transducer for high-frequency intravascular ultrasound (IVUS) imaging

In this paper, we report the use of micromachined PbIn1/2Nb1/2O3-PbMg1/3Nb2/3O3-PbTiO 3 (PIN-PMNPT) single crystal 1-3 composite material for intravascular ultrasound (IVUS) imaging application. The effective electromechanical coupling coefficient kt(eff) of the composite was measured to be 0.75 to...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 61(2014), 7 vom: 23. Juli, Seite 1171-8
1. Verfasser: Li, Xiang (VerfasserIn)
Weitere Verfasser: Ma, Teng, Tian, Jian, Han, Pengdi, Zhou, Qifa, Shung, K Kirk
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2014
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article Research Support, N.I.H., Extramural
LEADER 01000caa a22002652 4500
001 NLM239483294
003 DE-627
005 20250217051207.0
007 cr uuu---uuuuu
008 231224s2014 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2014.3016  |2 doi 
028 5 2 |a pubmed25n0798.xml 
035 |a (DE-627)NLM239483294 
035 |a (NLM)24960706 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Li, Xiang  |e verfasserin  |4 aut 
245 1 0 |a Micromachined PIN-PMN-PT crystal composite transducer for high-frequency intravascular ultrasound (IVUS) imaging 
264 1 |c 2014 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 21.04.2015 
500 |a Date Revised 21.10.2021 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a In this paper, we report the use of micromachined PbIn1/2Nb1/2O3-PbMg1/3Nb2/3O3-PbTiO 3 (PIN-PMNPT) single crystal 1-3 composite material for intravascular ultrasound (IVUS) imaging application. The effective electromechanical coupling coefficient kt(eff) of the composite was measured to be 0.75 to 0.78. Acoustic impedance was estimated to be 20 MRayl. Based on the composite, needle-type and flexible-type IVUS transducers were fabricated. The composite transducer achieved an 86% bandwidth at the center frequency of 41 MHz, which resulted in a 43 μm axial resolution. Ex vivo IVUS imaging was conducted to demonstrate the improvement of axial resolution. The composite transducer was capable of identifying the three layers of a cadaver coronary artery specimen with high resolution. The PIN-PMN-PT-based composite has superior piezoelectric properties comparable to PMN-PT-based composite and its thermal stability is higher than PMN-PT. PIN-PMN-PT crystal can be an alternative approach for fabricating high-frequency composite, instead of using PMN-PT 
650 4 |a Journal Article 
650 4 |a Research Support, N.I.H., Extramural 
700 1 |a Ma, Teng  |e verfasserin  |4 aut 
700 1 |a Tian, Jian  |e verfasserin  |4 aut 
700 1 |a Han, Pengdi  |e verfasserin  |4 aut 
700 1 |a Zhou, Qifa  |e verfasserin  |4 aut 
700 1 |a Shung, K Kirk  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 61(2014), 7 vom: 23. Juli, Seite 1171-8  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:61  |g year:2014  |g number:7  |g day:23  |g month:07  |g pages:1171-8 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2014.3016  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 61  |j 2014  |e 7  |b 23  |c 07  |h 1171-8