X-ray harmonics rejection on third-generation synchrotron sources using compound refractive lenses

A new method of harmonics rejection based on X-ray refractive optics has been proposed. Taking into account the fact that the focal distance of the refractive lens is energy-dependent, the use of an off-axis illumination of the lens immediately leads to spatial separation of the energy spectrum by f...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 21(2014), Pt 3 vom: 01. Mai, Seite 484-7
1. Verfasser: Polikarpov, Maxim (VerfasserIn)
Weitere Verfasser: Snigireva, Irina, Snigirev, Anatoly
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2014
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't X-ray refraction X-ray refractive lenses focusing harmonic suppression
LEADER 01000caa a22002652 4500
001 NLM237662140
003 DE-627
005 20250216231132.0
007 cr uuu---uuuuu
008 231224s2014 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577514001003  |2 doi 
028 5 2 |a pubmed25n0792.xml 
035 |a (DE-627)NLM237662140 
035 |a (NLM)24763636 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Polikarpov, Maxim  |e verfasserin  |4 aut 
245 1 0 |a X-ray harmonics rejection on third-generation synchrotron sources using compound refractive lenses 
264 1 |c 2014 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 30.09.2015 
500 |a Date Revised 25.04.2014 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a A new method of harmonics rejection based on X-ray refractive optics has been proposed. Taking into account the fact that the focal distance of the refractive lens is energy-dependent, the use of an off-axis illumination of the lens immediately leads to spatial separation of the energy spectrum by focusing the fundamental harmonic at the focal point and suppressing the unfocused high-energy radiation with a screen absorber or slit. The experiment was performed at the ESRF ID06 beamline in the in-line geometry using an X-ray transfocator with compound refractive lenses. Using this technique the presence of the third harmonic has been reduced to 10(-3). In total, our method enabled suppression of all higher-order harmonics to five orders of magnitude using monochromator detuning. The method is well suited to third-generation synchrotron radiation sources and is very promising for the future ultimate storage rings 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a X-ray refraction 
650 4 |a X-ray refractive lenses 
650 4 |a focusing 
650 4 |a harmonic suppression 
700 1 |a Snigireva, Irina  |e verfasserin  |4 aut 
700 1 |a Snigirev, Anatoly  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 21(2014), Pt 3 vom: 01. Mai, Seite 484-7  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:21  |g year:2014  |g number:Pt 3  |g day:01  |g month:05  |g pages:484-7 