Survey of point-of-care instrumentation, analysis, and quality assurance in veterinary practice

© 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.

Bibliographische Detailangaben
Veröffentlicht in:Veterinary clinical pathology. - 1975. - 43(2014), 2 vom: 20. Juni, Seite 185-92
1. Verfasser: Bell, Regan (VerfasserIn)
Weitere Verfasser: Harr, Kendal, Rishniw, Mark, Pion, Paul
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2014
Zugriff auf das übergeordnete Werk:Veterinary clinical pathology
Schlagworte:Journal Article Laboratory error laboratory standards reference interval veterinary in-clinic analysis
LEADER 01000caa a22002652c 4500
001 NLM237537613
003 DE-627
005 20250216224745.0
007 cr uuu---uuuuu
008 231224s2014 xx |||||o 00| ||eng c
024 7 |a 10.1111/vcp.12142  |2 doi 
028 5 2 |a pubmed25n0791.xml 
035 |a (DE-627)NLM237537613 
035 |a (NLM)24750496 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Bell, Regan  |e verfasserin  |4 aut 
245 1 0 |a Survey of point-of-care instrumentation, analysis, and quality assurance in veterinary practice 
264 1 |c 2014 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 16.04.2015 
500 |a Date Revised 20.10.2016 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology. 
520 |a BACKGROUND: While there have been ASVCP meeting discussions regarding quality assurance plans and lack thereof for in-clinic analyzers, there are little published data regarding in-clinic quality assurance and control practices 
520 |a OBJECTIVES: The purpose of this study was the identification of the common equipment used in hematologic, biochemical, urinalysis, and other testing, and assessment of quality control and assurance programs currently being performed in-clinic 
520 |a METHODS: All members of the Veterinary Information Network (VIN) were solicited to participate in an online survey between July and September 2007 
520 |a RESULTS: In total, 452 complete or partial responses were received. Eighty-nine percent of respondents (361/404) said that veterinary technicians (unlicensed, licensed, and registered) performed the majority of analyses. Eighty-eight percent (366/417) of respondents performed some quality assurance on their laboratory equipment, most commonly on chemistry (91%, 324/357), and hematology (84%, 292/347) analyzers, and least commonly on fecal analyses (57%, 148/260) and ELISA assays (25%, 65/256). Ignorance of how to perform quality assurance was the most commonly stated reason (49%, 25/51) for lack of a quality assurance program. The majority of practices (316/374) utilized manufacturer-provided reference intervals without further adjustment or assessment. Roughly one-third of respondents (126/374) used reference intervals from textbooks, which is discouraged by ASVCP guidelines 
520 |a CONCLUSIONS: This study found that the majority of respondents were not in compliance with ASVCP guidelines, illustrating the need for improved education of technical staff, veterinary students, and veterinarians regarding limitations of in-clinic laboratory equipment and the importance of regular quality control, maintenance, training, and reference interval development 
650 4 |a Journal Article 
650 4 |a Laboratory error 
650 4 |a laboratory standards 
650 4 |a reference interval 
650 4 |a veterinary in-clinic analysis 
700 1 |a Harr, Kendal  |e verfasserin  |4 aut 
700 1 |a Rishniw, Mark  |e verfasserin  |4 aut 
700 1 |a Pion, Paul  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Veterinary clinical pathology  |d 1975  |g 43(2014), 2 vom: 20. Juni, Seite 185-92  |w (DE-627)NLM098159984  |x 1939-165X  |7 nnas 
773 1 8 |g volume:43  |g year:2014  |g number:2  |g day:20  |g month:06  |g pages:185-92 
856 4 0 |u http://dx.doi.org/10.1111/vcp.12142  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 