Bifunctional designed peptides induce mineralization and binding to TiO2

A limitation of titanium implants is the rather poor bonding between the metal and the surrounding tissue. In this research, we aimed at developing functional peptides in the form of monomolecular coatings intended to improve adhesion between the native oxide of the metal (TiO2) and the calcium-phos...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1992. - 30(2014), 16 vom: 29. Apr., Seite 4716-24
1. Verfasser: Gitelman, Anna (VerfasserIn)
Weitere Verfasser: Rapaport, Hanna
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2014
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Calcium Phosphates Peptides titanium dioxide 15FIX9V2JP calcium phosphate 97Z1WI3NDX Titanium D1JT611TNE
Beschreibung
Zusammenfassung:A limitation of titanium implants is the rather poor bonding between the metal and the surrounding tissue. In this research, we aimed at developing functional peptides in the form of monomolecular coatings intended to improve adhesion between the native oxide of the metal (TiO2) and the calcium-phosphate mineralization layer with which it is in contact. Accordingly, a bifunctional peptide with a β-strand motif assumed to strongly bind to the oxide through two phosphorylated serine residues, both situated on the same face of the strand, was designed. The β-strand motif was extended by a mineralization "tail" composed of consecutive acidic amino acids capable of adsorbing calcium ions. This peptide was studied together with two additional control peptides, one serving to elucidate the role of the β-strand in stabilizing bonding with the oxide and the other demonstrating the ability of the tail to induce mineralization. The strong adsorption of the three peptides to the oxide surface was revealed by HPLC. That peptide presenting the mineralization tail showed the highest levels of adsorbed calcium and phosphate ions, as well as the largest area of cellular adherence, demonstrating its potential advantages for use with titanium implants in bone tissue
Beschreibung:Date Completed 15.04.2015
Date Revised 29.04.2014
published: Print-Electronic
Citation Status MEDLINE
ISSN:1520-5827
DOI:10.1021/la500310n