Design considerations and performance of MEMS acoustoelectric ultrasound detectors

Most single-element hydrophones depend on a piezoelectric material that converts pressure changes to electricity. These devices, however, can be expensive, susceptible to damage at high pressure, and/or have limited bandwidth and sensitivity. We have previously described the acoustoelectric (AE) hyd...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 60(2013), 9 vom: 28. Sept., Seite 1906-16
1. Verfasser: Wang, Zhaohui (VerfasserIn)
Weitere Verfasser: Ingram, Pier, Greenlee, Charles L, Olafsson, Ragnar, Norwood, Robert A, Witte, Russell S
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2013
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't
LEADER 01000naa a22002652 4500
001 NLM236662201
003 DE-627
005 20231224110032.0
007 cr uuu---uuuuu
008 231224s2013 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2013.2775  |2 doi 
028 5 2 |a pubmed24n0788.xml 
035 |a (DE-627)NLM236662201 
035 |a (NLM)24658721 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Wang, Zhaohui  |e verfasserin  |4 aut 
245 1 0 |a Design considerations and performance of MEMS acoustoelectric ultrasound detectors 
264 1 |c 2013 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 18.11.2014 
500 |a Date Revised 21.10.2021 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Most single-element hydrophones depend on a piezoelectric material that converts pressure changes to electricity. These devices, however, can be expensive, susceptible to damage at high pressure, and/or have limited bandwidth and sensitivity. We have previously described the acoustoelectric (AE) hydrophone as an inexpensive alternative for mapping an ultrasound beam and monitoring acoustic exposure. The device exploits the AE effect, an interaction between electrical current flowing through a material and a propagating pressure wave. Previous designs required imprecise fabrication methods using common laboratory supplies, making it difficult to control basic features such as shape and size. This study describes a different approach based on microelectromechanical systems (MEMS) processing that allows for much finer control of several design features. In an effort to improve the performance of the AE hydrophone, we combine simulations with bench-top testing to evaluate key design features, such as thickness, shape, and conductivity of the active and passive elements. The devices were evaluated in terms of sensitivity, frequency response, and accuracy for reproducing the beam pattern. Our simulations and experimental results both indicated that designs using a combination of indium tin oxide (ITO) for the active element and gold for the passive electrodes (conductivity ratio = ~20) produced the best result for mapping the beam of a 2.25-MHz ultrasound transducer. Also, the AE hydrophone with a rectangular dumbbell configuration achieved a better beam pattern than other shape configurations. Lateral and axial resolutions were consistent with images generated from a commercial capsule hydrophone. Sensitivity of the best-performing device was 1.52 nV/Pa at 500 kPa using a bias voltage of 20 V. We expect a thicker AE hydrophone closer to half the acoustic wavelength to produce even better sensitivity, while maintaining high spectral bandwidth for characterizing medical ultrasound transducers. AE ultrasound detectors may also be useful for monitoring acoustic exposure during therapy or as receivers for photoacoustic imaging 
650 4 |a Journal Article 
650 4 |a Research Support, N.I.H., Extramural 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Ingram, Pier  |e verfasserin  |4 aut 
700 1 |a Greenlee, Charles L  |e verfasserin  |4 aut 
700 1 |a Olafsson, Ragnar  |e verfasserin  |4 aut 
700 1 |a Norwood, Robert A  |e verfasserin  |4 aut 
700 1 |a Witte, Russell S  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 60(2013), 9 vom: 28. Sept., Seite 1906-16  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:60  |g year:2013  |g number:9  |g day:28  |g month:09  |g pages:1906-16 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2013.2775  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 60  |j 2013  |e 9  |b 28  |c 09  |h 1906-16