Object image correction using an X-ray dynamical diffraction Fraunhofer hologram

Taking into account background correction and using Fourier analysis, a numerical method of an object image correction using an X-ray dynamical diffraction Fraunhofer hologram is presented. An example of the image correction of a cylindrical beryllium wire is considered. A background correction of s...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 21(2014), Pt 2 vom: 07. März, Seite 449-51
1. Verfasser: Balyan, Minas K (VerfasserIn)
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2014
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article X-ray Fraunhofer holography X-ray dynamical diffraction X-ray microscopy image reconstruction
LEADER 01000naa a22002652 4500
001 NLM235786918
003 DE-627
005 20231224104137.0
007 cr uuu---uuuuu
008 231224s2014 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577513034802  |2 doi 
028 5 2 |a pubmed24n0786.xml 
035 |a (DE-627)NLM235786918 
035 |a (NLM)24562568 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Balyan, Minas K  |e verfasserin  |4 aut 
245 1 0 |a Object image correction using an X-ray dynamical diffraction Fraunhofer hologram 
264 1 |c 2014 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 20.10.2014 
500 |a Date Revised 24.02.2014 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Taking into account background correction and using Fourier analysis, a numerical method of an object image correction using an X-ray dynamical diffraction Fraunhofer hologram is presented. An example of the image correction of a cylindrical beryllium wire is considered. A background correction of second-order iteration leads to an almost precise reconstruction of the real part of the amplitude transmission coefficient and improves the imaginary part compared with that without a background correction. Using Fourier analysis of the reconstructed transmission coefficient, non-physical oscillations can be avoided. This method can be applied for the determination of the complex amplitude transmission coefficient of amplitude as well as phase objects, and can be used in X-ray microscopy 
650 4 |a Journal Article 
650 4 |a X-ray Fraunhofer holography 
650 4 |a X-ray dynamical diffraction 
650 4 |a X-ray microscopy 
650 4 |a image reconstruction 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 21(2014), Pt 2 vom: 07. März, Seite 449-51  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:21  |g year:2014  |g number:Pt 2  |g day:07  |g month:03  |g pages:449-51 
856 4 0 |u http://dx.doi.org/10.1107/S1600577513034802  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 21  |j 2014  |e Pt 2  |b 07  |c 03  |h 449-51