In situ micro-focused X-ray beam characterization with a lensless camera using a hybrid pixel detector

Results of studies on micro-focused X-ray beam diagnostics using an X-ray beam imaging (XBI) instrument based on the idea of recording radiation scattered from a thin foil of a low-Z material with a lensless camera are reported. The XBI instrument captures magnified images of the scattering region w...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 21(2014), Pt 2 vom: 07. März, Seite 333-9
1. Verfasser: Kachatkou, Anton (VerfasserIn)
Weitere Verfasser: Marchal, Julien, van Silfhout, Roelof
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2014
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't X-ray imaging beam diagnostics beam size measurements micro-focus pinhole camera scattering measurements
LEADER 01000caa a22002652 4500
001 NLM235786772
003 DE-627
005 20250216175555.0
007 cr uuu---uuuuu
008 231224s2014 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577513034759  |2 doi 
028 5 2 |a pubmed25n0785.xml 
035 |a (DE-627)NLM235786772 
035 |a (NLM)24562554 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kachatkou, Anton  |e verfasserin  |4 aut 
245 1 0 |a In situ micro-focused X-ray beam characterization with a lensless camera using a hybrid pixel detector 
264 1 |c 2014 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 20.10.2014 
500 |a Date Revised 21.10.2021 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Results of studies on micro-focused X-ray beam diagnostics using an X-ray beam imaging (XBI) instrument based on the idea of recording radiation scattered from a thin foil of a low-Z material with a lensless camera are reported. The XBI instrument captures magnified images of the scattering region within the foil as illuminated by the incident beam. These images contain information about beam size, beam position and beam intensity that is extracted during dedicated signal processing steps. In this work the use of the device with beams for which the beam size is significantly smaller than that of a single detector pixel is explored. The performance of the XBI device equipped with a state-of-the-art hybrid pixel X-ray imaging sensor is analysed. Compared with traditional methods such as slit edge or wire scanners, the XBI micro-focused beam characterization is significantly faster and does not interfere with on-going experiments. The challenges associated with measuring micrometre-sized beams are described and ways of optimizing the resolution of beam position and size measurements of the XBI instrument are discussed 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a X-ray imaging 
650 4 |a beam diagnostics 
650 4 |a beam size measurements 
650 4 |a micro-focus 
650 4 |a pinhole camera 
650 4 |a scattering measurements 
700 1 |a Marchal, Julien  |e verfasserin  |4 aut 
700 1 |a van Silfhout, Roelof  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 21(2014), Pt 2 vom: 07. März, Seite 333-9  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:21  |g year:2014  |g number:Pt 2  |g day:07  |g month:03  |g pages:333-9 
856 4 0 |u http://dx.doi.org/10.1107/S1600577513034759  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 21  |j 2014  |e Pt 2  |b 07  |c 03  |h 333-9