Hybrid pixel-waveform CdTe/CZT detector for use in an ultrahigh resolution MRI compatible SPECT system

In this paper, we will present a new small pixel CdTe/CZT detector for sub-500 μm resolution SPECT imaging application inside MR scanner based on a recently developed hybrid pixel-waveform (HPWF) readout circuitry. The HPWF readout system consists of a 2-D multi-pixel circuitry attached to the anode...

Description complète

Détails bibliographiques
Publié dans:Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment. - 1987. - 702(2013) vom: 01. Feb.
Auteur principal: Cai, Liang (Auteur)
Autres auteurs: Meng, Ling-Jian
Format: Article en ligne
Langue:English
Publié: 2013
Accès à la collection:Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
Sujets:Journal Article CdTe/CZT Hybrid pixel-waveform readout MR compatible SPECT
LEADER 01000caa a22002652c 4500
001 NLM233976132
003 DE-627
005 20250216120242.0
007 cr uuu---uuuuu
008 231224s2013 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.nima.2012.08.069  |2 doi 
028 5 2 |a pubmed25n0779.xml 
035 |a (DE-627)NLM233976132 
035 |a (NLM)24371365 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Cai, Liang  |e verfasserin  |4 aut 
245 1 0 |a Hybrid pixel-waveform CdTe/CZT detector for use in an ultrahigh resolution MRI compatible SPECT system 
264 1 |c 2013 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 10.11.2023 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a In this paper, we will present a new small pixel CdTe/CZT detector for sub-500 μm resolution SPECT imaging application inside MR scanner based on a recently developed hybrid pixel-waveform (HPWF) readout circuitry. The HPWF readout system consists of a 2-D multi-pixel circuitry attached to the anode pixels to provide the X-Y positions of interactions, and a high-speed digitizer to read out the pulse-waveform induced on the cathode. The digitized cathode waveform could provide energy deposition information, precise timing and depth-of-interaction information for gamma ray interactions. Several attractive features with this HPWF detector system will be discussed in this paper. To demonstrate the performance, we constructed several prototype HPWF detectors with pixelated CZT and CdTe detectors of 2-5 mm thicknesses, connected to a prototype readout system consisting of energy-resolved photon-counting ASIC for readout anode pixels and an Agilent high-speed digitizer for digitizing the cathode signals. The performances of these detectors based on HPWF are discussed in this paper 
650 4 |a Journal Article 
650 4 |a CdTe/CZT 
650 4 |a Hybrid pixel-waveform readout 
650 4 |a MR compatible SPECT 
700 1 |a Meng, Ling-Jian  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment  |d 1987  |g 702(2013) vom: 01. Feb.  |w (DE-627)NLM098171771  |x 0168-9002  |7 nnas 
773 1 8 |g volume:702  |g year:2013  |g day:01  |g month:02 
856 4 0 |u http://dx.doi.org/10.1016/j.nima.2012.08.069  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 702  |j 2013  |b 01  |c 02