Laboratory test for ice adhesion strength using commercial instrumentation

A laboratory test method for evaluating ice adhesion has been developed employing a commercially available instrument normally used for dynamic mechanical analysis (TA RSA-III). This is the first laboratory ice adhesion test that does not require a custom-built apparatus. The upper grip range of ∼10...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1992. - 30(2014), 2 vom: 21. Jan., Seite 540-7
1. Verfasser: Wang, Chenyu (VerfasserIn)
Weitere Verfasser: Zhang, Wei, Siva, Adarsh, Tiea, Daniel, Wynne, Kenneth J
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2014
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM233943382
003 DE-627
005 20231224100207.0
007 cr uuu---uuuuu
008 231224s2014 xx |||||o 00| ||eng c
024 7 |a 10.1021/la4044254  |2 doi 
028 5 2 |a pubmed24n0779.xml 
035 |a (DE-627)NLM233943382 
035 |a (NLM)24367944 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Wang, Chenyu  |e verfasserin  |4 aut 
245 1 0 |a Laboratory test for ice adhesion strength using commercial instrumentation 
264 1 |c 2014 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 08.09.2014 
500 |a Date Revised 21.01.2014 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a A laboratory test method for evaluating ice adhesion has been developed employing a commercially available instrument normally used for dynamic mechanical analysis (TA RSA-III). This is the first laboratory ice adhesion test that does not require a custom-built apparatus. The upper grip range of ∼10 mm is an enabling feature that is essential for the test. The method involves removal of an ice cylinder from a polymer coating with a probe and the determination of peak removal force (Ps). To validate the test method, the strength of ice adhesion was determined for a prototypical glassy polymer, poly(methyl methacrylate). The distance of the probe from the PMMA surface has been identified as a critical variable for Ps. The new test provides a readily available platform for investigating fundamental surface characteristics affecting ice adhesion. In addition to the ice release test, PMMA coatings were characterized using DSC, DCA, and TM-AFM 
650 4 |a Journal Article 
700 1 |a Zhang, Wei  |e verfasserin  |4 aut 
700 1 |a Siva, Adarsh  |e verfasserin  |4 aut 
700 1 |a Tiea, Daniel  |e verfasserin  |4 aut 
700 1 |a Wynne, Kenneth J  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1992  |g 30(2014), 2 vom: 21. Jan., Seite 540-7  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnns 
773 1 8 |g volume:30  |g year:2014  |g number:2  |g day:21  |g month:01  |g pages:540-7 
856 4 0 |u http://dx.doi.org/10.1021/la4044254  |3 Volltext 