Momentum-resolved resonant inelastic X-ray scattering on a single crystal under high pressure

A single-crystal momentum-resolved resonant inelastic X-ray scattering (RIXS) experiment under high pressure using an originally designed diamond anvil cell (DAC) is reported. The diamond-in/diamond-out geometry was adopted with both the incident and scattered beams passing through a 1 mm-thick diam...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 21(2014), Pt 1 vom: 15. Jan., Seite 131-5
1. Verfasser: Yoshida, Masahiro (VerfasserIn)
Weitere Verfasser: Ishii, Kenji, Jarrige, Ignace, Watanuki, Tetsu, Kudo, Kazutaka, Koike, Yoji, Kumagai, Ken'ichi, Hiraoka, Nozomu, Ishii, Hirofumi, Tsuei, Ku-Ding, Mizuki, Jun'ichiro
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2014
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article diamond anvil cell electronic excitations high pressure resonant inelastic X-ray scattering
LEADER 01000naa a22002652 4500
001 NLM233924035
003 DE-627
005 20231224100142.0
007 cr uuu---uuuuu
008 231224s2014 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577513028944  |2 doi 
028 5 2 |a pubmed24n0779.xml 
035 |a (DE-627)NLM233924035 
035 |a (NLM)24365927 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Yoshida, Masahiro  |e verfasserin  |4 aut 
245 1 0 |a Momentum-resolved resonant inelastic X-ray scattering on a single crystal under high pressure 
264 1 |c 2014 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 15.08.2014 
500 |a Date Revised 24.12.2013 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a A single-crystal momentum-resolved resonant inelastic X-ray scattering (RIXS) experiment under high pressure using an originally designed diamond anvil cell (DAC) is reported. The diamond-in/diamond-out geometry was adopted with both the incident and scattered beams passing through a 1 mm-thick diamond. This enabled us to cover wide momentum space keeping the scattering angle condition near 90°. Elastic and inelastic scattering from the diamond was drastically reduced using a pinhole placed after the DAC. Measurement of the momentum-resolved RIXS spectra of Sr2.5Ca11.5Cu24O41 at the Cu K-edge was thus successful. Though the inelastic intensity becomes weaker by two orders than the ambient pressure, RIXS spectra both at the center and the edge of the Brillouin zone were obtained at 3 GPa and low-energy electronic excitations of the cuprate were found to change with pressure 
650 4 |a Journal Article 
650 4 |a diamond anvil cell 
650 4 |a electronic excitations 
650 4 |a high pressure 
650 4 |a resonant inelastic X-ray scattering 
700 1 |a Ishii, Kenji  |e verfasserin  |4 aut 
700 1 |a Jarrige, Ignace  |e verfasserin  |4 aut 
700 1 |a Watanuki, Tetsu  |e verfasserin  |4 aut 
700 1 |a Kudo, Kazutaka  |e verfasserin  |4 aut 
700 1 |a Koike, Yoji  |e verfasserin  |4 aut 
700 1 |a Kumagai, Ken'ichi  |e verfasserin  |4 aut 
700 1 |a Hiraoka, Nozomu  |e verfasserin  |4 aut 
700 1 |a Ishii, Hirofumi  |e verfasserin  |4 aut 
700 1 |a Tsuei, Ku-Ding  |e verfasserin  |4 aut 
700 1 |a Mizuki, Jun'ichiro  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 21(2014), Pt 1 vom: 15. Jan., Seite 131-5  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:21  |g year:2014  |g number:Pt 1  |g day:15  |g month:01  |g pages:131-5 
856 4 0 |u http://dx.doi.org/10.1107/S1600577513028944  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 21  |j 2014  |e Pt 1  |b 15  |c 01  |h 131-5