Numerical reconstruction of an object image using an X-ray dynamical diffraction Fraunhofer hologram

A numerical method of reconstruction of an object image using an X-ray dynamical diffraction Fraunhofer hologram is presented. Analytical approximation methods and numerical methods of iteration are discussed. An example of a reconstruction of an image of a cylindrical beryllium wire is considered....

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 21(2014), Pt 1 vom: 15. Jan., Seite 127-30
1. Verfasser: Balyan, Minas K (VerfasserIn)
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2014
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article X-ray Fraunhofer holography X-ray dynamical diffraction X-ray microscopy image processing
LEADER 01000naa a22002652 4500
001 NLM233924027
003 DE-627
005 20231224100142.0
007 cr uuu---uuuuu
008 231224s2014 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577513029317  |2 doi 
028 5 2 |a pubmed24n0779.xml 
035 |a (DE-627)NLM233924027 
035 |a (NLM)24365926 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Balyan, Minas K  |e verfasserin  |4 aut 
245 1 0 |a Numerical reconstruction of an object image using an X-ray dynamical diffraction Fraunhofer hologram 
264 1 |c 2014 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 15.08.2014 
500 |a Date Revised 24.12.2013 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a A numerical method of reconstruction of an object image using an X-ray dynamical diffraction Fraunhofer hologram is presented. Analytical approximation methods and numerical methods of iteration are discussed. An example of a reconstruction of an image of a cylindrical beryllium wire is considered. The results of analytical approximation and zero-order iteration coincide with exact values of the amplitude complex transmission coefficient of the object as predicted by the resolution limit of the scheme, except near the edges of the object. Calculations of the first- and second-order iterations improve the result at the edges of the object. This method can be applied for determination of the complex amplitude transmission coefficient of amplitude as well as phase objects. It can be used in X-ray microscopy 
650 4 |a Journal Article 
650 4 |a X-ray Fraunhofer holography 
650 4 |a X-ray dynamical diffraction 
650 4 |a X-ray microscopy 
650 4 |a image processing 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 21(2014), Pt 1 vom: 15. Jan., Seite 127-30  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:21  |g year:2014  |g number:Pt 1  |g day:15  |g month:01  |g pages:127-30 
856 4 0 |u http://dx.doi.org/10.1107/S1600577513029317  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 21  |j 2014  |e Pt 1  |b 15  |c 01  |h 127-30