Piezoelectric fiber-composite-based cantilever sensor for electric-field-induced strain measurement in soft electroactive polymer

Polymeric materials have been widely used in electronic and electromechanical transducer applications. Because of their low elastic modulus, it is quite challenging to accurately characterize the electric-field-induced strain and elastic modulus by conventional contact methods. In this paper, a piez...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 60(2013), 10 vom: 14. Okt., Seite 2142-53
1. Verfasser: Chen, Qian (VerfasserIn)
Weitere Verfasser: Sun, Yingying, Qin, Lifeng, Wang, Qing-Ming
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2013
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM231295790
003 DE-627
005 20250216000044.0
007 cr uuu---uuuuu
008 231224s2013 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2013.2805  |2 doi 
028 5 2 |a pubmed25n0771.xml 
035 |a (DE-627)NLM231295790 
035 |a (NLM)24081263 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Chen, Qian  |e verfasserin  |4 aut 
245 1 0 |a Piezoelectric fiber-composite-based cantilever sensor for electric-field-induced strain measurement in soft electroactive polymer 
264 1 |c 2013 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 06.05.2014 
500 |a Date Revised 01.10.2013 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Polymeric materials have been widely used in electronic and electromechanical transducer applications. Because of their low elastic modulus, it is quite challenging to accurately characterize the electric-field-induced strain and elastic modulus by conventional contact methods. In this paper, a piezoelectric lead zirconate titanate (PZT) fiber-composite-based cantilever strain sensor has been investigated to accurately characterize the electric-field-induced strain response in the out-of-plane direction of soft electroactive polymer samples. By choosing appropriate substrate material and the thickness ratio of the fiber composite to the substrate, this strain sensor can be optimized to provide high sensitivity and high flexibility simultaneously. The high voltage sensitivity can be attributed to partial decoupling of the longitudinal and transverse piezoelectric responses, the improved piezoelectric coefficient and small dielectric permittivity. The high flexibility is due to the reduced flexural spring constant of the composite-based cantilever device. Both theoretical modeling of the PZT fiber-composite-based cantilever device and experimental verification are performed in this work. The results indicate that the piezoelectric PZT fiber-composite-based cantilever strain sensor can accurately characterize the electric-field-induced small strain in electroactive soft polymers with high reliability 
650 4 |a Journal Article 
700 1 |a Sun, Yingying  |e verfasserin  |4 aut 
700 1 |a Qin, Lifeng  |e verfasserin  |4 aut 
700 1 |a Wang, Qing-Ming  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 60(2013), 10 vom: 14. Okt., Seite 2142-53  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:60  |g year:2013  |g number:10  |g day:14  |g month:10  |g pages:2142-53 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2013.2805  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 60  |j 2013  |e 10  |b 14  |c 10  |h 2142-53