Initial experience of using intracardiac echocardiography (ICE) for guiding balloon mitral valvuloplasty (BMV)

BACKGROUND AND AIMS: BMV is an established treatment for rheumatic mitral valve stenosis. The procedure is historically guided by fluoroscopy, and the role of intracardiac echocardiogram (ICE) guidance is not well defined. We report our initial experience of using ICE to guide BMV procedures

Bibliographische Detailangaben
Veröffentlicht in:Journal of the Saudi Heart Association. - 1999. - 24(2012), 1 vom: 20. Jan., Seite 23-7
1. Verfasser: Ahmari, Saeed Al (VerfasserIn)
Weitere Verfasser: Amro, Ahmed, Otabi, Mohammed Al, Abdullah, Moheeb Al, Kasab, Saad Al, Amri, Husien Al
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2012
Zugriff auf das übergeordnete Werk:Journal of the Saudi Heart Association
Schlagworte:Journal Article Balloon valvuloplasty Echocardiography Mitral stenosis
Beschreibung
Zusammenfassung:BACKGROUND AND AIMS: BMV is an established treatment for rheumatic mitral valve stenosis. The procedure is historically guided by fluoroscopy, and the role of intracardiac echocardiogram (ICE) guidance is not well defined. We report our initial experience of using ICE to guide BMV procedures
METHODS: During BMV procedure, ICE catheter was inserted into the right atrium from the right femoral vein, and the septal puncture was monitored by ICE, as well as positioning of the balloon in the mitral valve. Comparisons were made between ICE, transthoracic echocardiography (TTE), and catheterization derived hemodynamic measurements (cath)
RESULTS: Seventeen patients with mitral stenosis underwent the procedure. The mean age was 44.4 ± 21 years. The mean MV area increased from 0.9 ± 0.1 cm(2) to 1.7 ± 0.2 cm(2), P < 0.0001 and the mean gradient decreased from 12.6 ± 5.8 mmHg to 4.9 ± 1.8 mmHg, P < 0.001. Atrial septum puncture and guidance of the balloon into the MV apparatus were obtained in all patients under ICE guidance. Severe MR developed in one patient and was readily detected by ICE. ICE derived gradient measurements were comparable to those obtained by TTE, and cath
CONCLUSION: ICE guidance of BMV is feasible, and useful in monitoring safe septal puncture, optimizing balloon positioning, and in detecting complications. The hemodynamic measurements obtained were comparable to those obtained by TTE, and cath