Response surface method for the optimisation of micropollutant removal in municipal wastewater treatment plant effluent with the UV/H2O2 advanced oxidation process

Experiments with the ultraviolet (UV)/H2O2 advanced oxidation process (AOP) were conducted to investigate the abatement of micropollutants in wastewater treatment plant effluent. The fluence and the starting concentration of H2O2 in a bench-scale batch reactor were varied according to response surfa...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 67(2013), 9 vom: 08., Seite 2075-82
1. Verfasser: Schulze-Hennings, U (VerfasserIn)
Weitere Verfasser: Pinnekamp, J
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2013
Zugriff auf das übergeordnete Werk:Water science and technology : a journal of the International Association on Water Pollution Research
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Waste Water Water Pollutants Hydrogen Peroxide BBX060AN9V