Higher torsional mode suppression in a pipe for enhancing the first torsional mode by using magnetostrictive patch transducers

Small-sized defects in pipes can be better detected if the first nondispersive torsional mode is used in a higher frequency range. However, dispersive higher torsional modes accompany the first mode if the actuation frequency is above the first cutoff frequency, thereby making the detection difficul...

Description complète

Détails bibliographiques
Publié dans:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 60(2013), 3 vom: 01. März, Seite 562-72
Auteur principal: Kim, Hoe Woong (Auteur)
Autres auteurs: Kwon, Young Eui, Lee, Joo Kyung, Kim, Yoon Young
Format: Article en ligne
Langue:English
Publié: 2013
Accès à la collection:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Sujets:Journal Article Research Support, Non-U.S. Gov't
LEADER 01000caa a22002652c 4500
001 NLM225660792
003 DE-627
005 20250215030206.0
007 cr uuu---uuuuu
008 231224s2013 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2013.2597  |2 doi 
028 5 2 |a pubmed25n0752.xml 
035 |a (DE-627)NLM225660792 
035 |a (NLM)23475921 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kim, Hoe Woong  |e verfasserin  |4 aut 
245 1 0 |a Higher torsional mode suppression in a pipe for enhancing the first torsional mode by using magnetostrictive patch transducers 
264 1 |c 2013 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 20.08.2013 
500 |a Date Revised 11.03.2013 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Small-sized defects in pipes can be better detected if the first nondispersive torsional mode is used in a higher frequency range. However, dispersive higher torsional modes accompany the first mode if the actuation frequency is above the first cutoff frequency, thereby making the detection difficult. This study proposes a new technique that is particularly useful for guided torsional waves in a pipe; it enhances the desired first nondispersive mode and suppresses the undesired second mode. The technique uses two transmitting transducers separated by an optimized distance and actuated with an optimized delay time. Unlike previous methods, such as a method tuning the delay time for desired mode enhancement and tuning the distance for undesired mode suppression, the proposed approach determines both the distance and delay time mainly to suppress the undesired second mode. With the selected values, the desired first mode is substantially enhanced. This phenomenon is unique in torsional waves, not longitudinal waves, for which delay time and distance controlling methods have been developed. After wave simulations were carried out to show why the proposed method is more effective for the case of torsional waves, several experiments using magnetostrictive transducers were performed to demonstrate the effectiveness of the proposed method 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Kwon, Young Eui  |e verfasserin  |4 aut 
700 1 |a Lee, Joo Kyung  |e verfasserin  |4 aut 
700 1 |a Kim, Yoon Young  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 60(2013), 3 vom: 01. März, Seite 562-72  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnas 
773 1 8 |g volume:60  |g year:2013  |g number:3  |g day:01  |g month:03  |g pages:562-72 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2013.2597  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 60  |j 2013  |e 3  |b 01  |c 03  |h 562-72