Using synchrotron radiation angiography with a highly sensitive detector to identify impaired peripheral perfusion in rat pulmonary emphysema

Owing to limitations in spatial resolution and sensitivity, it is difficult for conventional angiography to detect minute changes of perfusion in diffuse lung diseases, including pulmonary emphysema (PE). However, a high-gain avalanche rushing amorphous photoconductor (HARP) detector can give high s...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 20(2013), Pt 2 vom: 21. März, Seite 376-82
1. Verfasser: Ito, Hiromichi (VerfasserIn)
Weitere Verfasser: Matsushita, Shonosuke, Hyodo, Kazuyuki, Sato, Yukio, Sakakibara, Yuzuru
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2013
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't HARP detector pulmonary emphysema pulmonary microcirculation sensitivity synchrotron radiation angiography Contrast Media
LEADER 01000caa a22002652c 4500
001 NLM225054493
003 DE-627
005 20250215003622.0
007 cr uuu---uuuuu
008 231224s2013 xx |||||o 00| ||eng c
024 7 |a 10.1107/S090904951300040X  |2 doi 
028 5 2 |a pubmed25n0750.xml 
035 |a (DE-627)NLM225054493 
035 |a (NLM)23412496 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Ito, Hiromichi  |e verfasserin  |4 aut 
245 1 0 |a Using synchrotron radiation angiography with a highly sensitive detector to identify impaired peripheral perfusion in rat pulmonary emphysema 
264 1 |c 2013 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 06.08.2013 
500 |a Date Revised 18.03.2024 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a Owing to limitations in spatial resolution and sensitivity, it is difficult for conventional angiography to detect minute changes of perfusion in diffuse lung diseases, including pulmonary emphysema (PE). However, a high-gain avalanche rushing amorphous photoconductor (HARP) detector can give high sensitivity to synchrotron radiation (SR) angiography. SR angiography with a HARP detector provides high spatial resolution and sensitivity in addition to time resolution owing to its angiographic nature. The purpose of this study was to investigate whether this SR angiography with a HARP detector could evaluate altered microcirculation in PE. Two groups of rats were used: group PE and group C (control). Transvenous SR angiography with a HARP detector was performed and histopathological findings were compared. Peak density of contrast material in peripheral lung was lower in group PE than group C (p < 0.01). The slope of the linear regression line in scattering diagrams was also lower in group PE than C (p < 0.05). The correlation between the slope and extent of PE in histopathology showed significant negative correlation (p < 0.05, r = 0.61). SR angiography with a HARP detector made it possible to identify impaired microcirculation in PE by means of its high spatial resolution and sensitivity 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a HARP detector 
650 4 |a pulmonary emphysema 
650 4 |a pulmonary microcirculation 
650 4 |a sensitivity 
650 4 |a synchrotron radiation angiography 
650 7 |a Contrast Media  |2 NLM 
700 1 |a Matsushita, Shonosuke  |e verfasserin  |4 aut 
700 1 |a Hyodo, Kazuyuki  |e verfasserin  |4 aut 
700 1 |a Sato, Yukio  |e verfasserin  |4 aut 
700 1 |a Sakakibara, Yuzuru  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 20(2013), Pt 2 vom: 21. März, Seite 376-82  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnas 
773 1 8 |g volume:20  |g year:2013  |g number:Pt 2  |g day:21  |g month:03  |g pages:376-82 
856 4 0 |u http://dx.doi.org/10.1107/S090904951300040X  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 20  |j 2013  |e Pt 2  |b 21  |c 03  |h 376-82