Heat bump on a monochromator crystal measured with X-ray grating interferometry

Deformation of the first crystal of an X-ray monochromator under the heat load of a high-power beam, commonly referred to as `heat bump', is a challenge frequently faced at synchrotron beamlines. Here, quantitative measurements of the deformations of an externally water-cooled silicon (111) dou...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 20(2013), Pt 2 vom: 21. März, Seite 300-5
1. Verfasser: Rutishauser, Simon (VerfasserIn)
Weitere Verfasser: Rack, Alexander, Weitkamp, Timm, Kayser, Yves, David, Christian, Macrander, Albert T
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2013
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, Non-P.H.S. double-crystal monochromator grating interferometry heat bump wavefront characterization