Sagittal focusing of synchrotron radiation X-rays using a winged crystal

A Si(111) winged crystal has been designed to minimize anticlastic bending and improve sagittal focusing efficiency. The crystal was thin with wide stiffening wings. The length-to-width ratio of the crystal was optimized by finite element analysis, and the optimal value was larger than the `golden v...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 20(2013), Pt 2 vom: 21. März, Seite 219-25
1. Verfasser: Nisawa, A (VerfasserIn)
Weitere Verfasser: Yoneda, Y, Ueno, G, Murakami, H, Okajima, Y, Yamamoto, K, Senba, Y, Uesugi, K, Tanaka, Y, Yamamoto, M, Goto, S, Ishikawa, T
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2013
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't SPring-8 crystal bender double-crystal monochromator sagittal focusing two-dimensional focusing winged crystal Muramidase EC 3.2.1.17
LEADER 01000caa a22002652 4500
001 NLM225054302
003 DE-627
005 20250215003619.0
007 cr uuu---uuuuu
008 231224s2013 xx |||||o 00| ||eng c
024 7 |a 10.1107/S0909049512049813  |2 doi 
028 5 2 |a pubmed25n0750.xml 
035 |a (DE-627)NLM225054302 
035 |a (NLM)23412477 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Nisawa, A  |e verfasserin  |4 aut 
245 1 0 |a Sagittal focusing of synchrotron radiation X-rays using a winged crystal 
264 1 |c 2013 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 06.08.2013 
500 |a Date Revised 23.03.2024 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a A Si(111) winged crystal has been designed to minimize anticlastic bending and improve sagittal focusing efficiency. The crystal was thin with wide stiffening wings. The length-to-width ratio of the crystal was optimized by finite element analysis, and the optimal value was larger than the `golden value'. The analysis showed that the slope error owing to anticlastic bending is less than the Darwin width. The X-rays were focused two-dimensionally using the crystal and a tangentially bent mirror. The observed profiles of the focal spot agreed well with the results of a ray-tracing calculation in the energy range from 8 to 17.5 keV. X-ray diffraction measurements with a high signal-to-noise ratio using this focusing system were demonstrated for a small protein crystal 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a SPring-8 
650 4 |a crystal bender 
650 4 |a double-crystal monochromator 
650 4 |a sagittal focusing 
650 4 |a two-dimensional focusing 
650 4 |a winged crystal 
650 7 |a Muramidase  |2 NLM 
650 7 |a EC 3.2.1.17  |2 NLM 
700 1 |a Yoneda, Y  |e verfasserin  |4 aut 
700 1 |a Ueno, G  |e verfasserin  |4 aut 
700 1 |a Murakami, H  |e verfasserin  |4 aut 
700 1 |a Okajima, Y  |e verfasserin  |4 aut 
700 1 |a Yamamoto, K  |e verfasserin  |4 aut 
700 1 |a Senba, Y  |e verfasserin  |4 aut 
700 1 |a Uesugi, K  |e verfasserin  |4 aut 
700 1 |a Tanaka, Y  |e verfasserin  |4 aut 
700 1 |a Yamamoto, M  |e verfasserin  |4 aut 
700 1 |a Goto, S  |e verfasserin  |4 aut 
700 1 |a Ishikawa, T  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 20(2013), Pt 2 vom: 21. März, Seite 219-25  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:20  |g year:2013  |g number:Pt 2  |g day:21  |g month:03  |g pages:219-25 
856 4 0 |u http://dx.doi.org/10.1107/S0909049512049813  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 20  |j 2013  |e Pt 2  |b 21  |c 03  |h 219-25