Using an in-vacuum CCD detector for simultaneous small- and wide-angle scattering at beamline X9

The implementation of simultaneous small- and wide-angle X-ray scattering at beamline X9 of the National Synchrotron Light Source is described. By utilizing an in-vacuum CCD detector with a truncated cone-shaped head and positioned at ~20° off-axis from the direct beam, the overlap of the scattering...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 20(2013), Pt 2 vom: 21. März, Seite 211-8
1. Verfasser: Yang, Lin (VerfasserIn)
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2013
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, U.S. Gov't, Non-P.H.S. GID GISAXS SAXS WAXS simultaneous Proteins
LEADER 01000naa a22002652 4500
001 NLM225054280
003 DE-627
005 20231224064301.0
007 cr uuu---uuuuu
008 231224s2013 xx |||||o 00| ||eng c
024 7 |a 10.1107/S0909049512048984  |2 doi 
028 5 2 |a pubmed24n0750.xml 
035 |a (DE-627)NLM225054280 
035 |a (NLM)23412476 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Yang, Lin  |e verfasserin  |4 aut 
245 1 0 |a Using an in-vacuum CCD detector for simultaneous small- and wide-angle scattering at beamline X9 
264 1 |c 2013 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 06.08.2013 
500 |a Date Revised 15.02.2013 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a The implementation of simultaneous small- and wide-angle X-ray scattering at beamline X9 of the National Synchrotron Light Source is described. By utilizing an in-vacuum CCD detector with a truncated cone-shaped head and positioned at ~20° off-axis from the direct beam, the overlap of the scattering angle coverage between the wide-angle detector and the conventional small-angle detector is maximized. The combined q-range for measurements in transmission geometry is typically 0.006-2.0 Å(-1) at 13.5 keV, with overlapping data within the range ~0.1-0.2 Å(-1). Simultaneous data collection can also be performed in grazing-incident measurements of flat substrate-supported samples, in which case the wide-angle detector can collect the scattering data along the sample normal as well as parallel to the sample surface without blocking the direct beam. Data processing and correction procedures will be discussed and examples presented 
650 4 |a Journal Article 
650 4 |a Research Support, U.S. Gov't, Non-P.H.S. 
650 4 |a GID 
650 4 |a GISAXS 
650 4 |a SAXS 
650 4 |a WAXS 
650 4 |a simultaneous 
650 7 |a Proteins  |2 NLM 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 20(2013), Pt 2 vom: 21. März, Seite 211-8  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:20  |g year:2013  |g number:Pt 2  |g day:21  |g month:03  |g pages:211-8 
856 4 0 |u http://dx.doi.org/10.1107/S0909049512048984  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 20  |j 2013  |e Pt 2  |b 21  |c 03  |h 211-8