Direct force measurement between bio-colloidal Giardia lamblia cysts and colloidal silicate glass particles

Force-separation measurements between Giardia lamblia cysts and an inorganic oxide (silicate glass) have been obtained by using an atomic force microscope (AFM). The cysts are compressible on the scale of the loads applied during force measurement, with the surface compressibility expressed in terms...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1985. - 28(2012), 49 vom: 11. Dez., Seite 17026-35
1. Verfasser: Virtanen, Anne-Mari J (VerfasserIn)
Weitere Verfasser: Considine, Robert F, Dixon, David R, Fong, Celesta, Drummond, Calum J
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2012
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Colloids Silicates
LEADER 01000caa a22002652c 4500
001 NLM222980176
003 DE-627
005 20250214164650.0
007 cr uuu---uuuuu
008 231224s2012 xx |||||o 00| ||eng c
024 7 |a 10.1021/la303331u  |2 doi 
028 5 2 |a pubmed25n0743.xml 
035 |a (DE-627)NLM222980176 
035 |a (NLM)23190196 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Virtanen, Anne-Mari J  |e verfasserin  |4 aut 
245 1 0 |a Direct force measurement between bio-colloidal Giardia lamblia cysts and colloidal silicate glass particles 
264 1 |c 2012 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 20.05.2013 
500 |a Date Revised 11.12.2012 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a Force-separation measurements between Giardia lamblia cysts and an inorganic oxide (silicate glass) have been obtained by using an atomic force microscope (AFM). The cysts are compressible on the scale of the loads applied during force measurement, with the surface compressibility expressed in terms of an interfacial spring constant (K(int)). The force of interaction prior to this Hookean region, on approach, is long-range and repulsive. The long-range force has been compared to models of the electrical double layer as well as an electrosteric layer. The comparison has led to the conclusion that the cyst surface can be described as a polyelectrolyte brush at intermediate separations (5-115 nm from linear compliance) with an electrical double layer often observed at larger separations. The dependence of the interaction force on surface retraction suggests that tethering between the cyst and siliceous surface can occur. The variation of the interaction with pH and upon variation with ionic strength has also been assessed. The information gained from the measurement of the interaction between G. lamblia and this model sandlike surface informs water treatment processes. Similar studies have been performed by us for the Cryptosporidium parvum (C. parvum) oocyst system to which this work is compared 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 7 |a Colloids  |2 NLM 
650 7 |a Silicates  |2 NLM 
700 1 |a Considine, Robert F  |e verfasserin  |4 aut 
700 1 |a Dixon, David R  |e verfasserin  |4 aut 
700 1 |a Fong, Celesta  |e verfasserin  |4 aut 
700 1 |a Drummond, Calum J  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1985  |g 28(2012), 49 vom: 11. Dez., Seite 17026-35  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnas 
773 1 8 |g volume:28  |g year:2012  |g number:49  |g day:11  |g month:12  |g pages:17026-35 
856 4 0 |u http://dx.doi.org/10.1021/la303331u  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_350 
912 |a GBV_ILN_721 
951 |a AR 
952 |d 28  |j 2012  |e 49  |b 11  |c 12  |h 17026-35