An energy-dispersive X-ray absorption spectroscopy beamline has been constructed at the Synchrotron Light Research Institute, Thailand. The beamline was designed to utilize the synchrotron radiation with photon energies between 2400 and 8000 eV. The horizontal focusing of the bent crystal in the ene...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 19(2012), Pt 6 vom: 01. Nov., Seite 937-43
1. Verfasser: Poo-arporn, Yingyot (VerfasserIn)
Weitere Verfasser: Chirawatkul, Prae, Saengsui, Worasarit, Chotiwan, Siwarak, Kityakarn, Sutasinee, Klinkhieo, Supat, Hormes, Josef, Songsiriritthigul, Prayoon
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2012
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM22206661X
003 DE-627
005 20231224053412.0
007 cr uuu---uuuuu
008 231224s2012 xx |||||o 00| ||eng c
024 7 |a 10.1107/S090904951204109X  |2 doi 
028 5 2 |a pubmed24n0740.xml 
035 |a (DE-627)NLM22206661X 
035 |a (NLM)23093752 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Poo-arporn, Yingyot  |e verfasserin  |4 aut 
245 1 0 |a Time-resolved XAS (Bonn-SUT-SLRI) beamline at SLRI 
264 1 |c 2012 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 18.03.2013 
500 |a Date Revised 24.10.2012 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a An energy-dispersive X-ray absorption spectroscopy beamline has been constructed at the Synchrotron Light Research Institute, Thailand. The beamline was designed to utilize the synchrotron radiation with photon energies between 2400 and 8000 eV. The horizontal focusing of the bent crystal in the energy-dispersive monochromator offers a small polychromatic focal spot of 1 mm at the sample position. By employing an energy-dispersive scheme, the whole X-ray absorption near-edge structure (XANES) can be obtained simultaneously using a position-sensitive detector with a fastest readout speed of 25 ms. The short data collection time opens a new opportunity for time-resolved X-ray absorption spectroscopy (XAS) experiments such as studies of changes of the electronic structures or the local coordination environments of an atom during a change in thermodynamic conditions. For this purpose, an in situ cell was designed and fabricated for the beamline. Thermal oxidation of TiO(2) was chosen as an in situ experiment example. The structural change of TiO(2) as a function of temperatures was monitored from the change in the measured XAS spectra. The obtained Ti K-edge XANES spectra clearly show the formation of an anatase phase when the temperature was raised to 673 K 
650 4 |a Journal Article 
700 1 |a Chirawatkul, Prae  |e verfasserin  |4 aut 
700 1 |a Saengsui, Worasarit  |e verfasserin  |4 aut 
700 1 |a Chotiwan, Siwarak  |e verfasserin  |4 aut 
700 1 |a Kityakarn, Sutasinee  |e verfasserin  |4 aut 
700 1 |a Klinkhieo, Supat  |e verfasserin  |4 aut 
700 1 |a Hormes, Josef  |e verfasserin  |4 aut 
700 1 |a Songsiriritthigul, Prayoon  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 19(2012), Pt 6 vom: 01. Nov., Seite 937-43  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:19  |g year:2012  |g number:Pt 6  |g day:01  |g month:11  |g pages:937-43 