Zone-doubled Fresnel zone plates for high-resolution hard X-ray full-field transmission microscopy

Full-field transmission X-ray microscopy is a unique non-destructive technique for three-dimensional imaging of specimens at the nanometer scale. Here, the use of zone-doubled Fresnel zone plates to achieve a spatial resolution better than 20 nm in the hard X-ray regime (8-10 keV) is reported. By ob...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 19(2012), Pt 5 vom: 23. Sept., Seite 705-9
1. Verfasser: Vila-Comamala, Joan (VerfasserIn)
Weitere Verfasser: Pan, Yongsheng, Lombardo, Jeffrey J, Harris, William M, Chiu, Wilson K S, David, Christian, Wang, Yuxin
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2012
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, U.S. Gov't, Non-P.H.S.
LEADER 01000caa a22002652 4500
001 NLM220284741
003 DE-627
005 20240324232024.0
007 cr uuu---uuuuu
008 231224s2012 xx |||||o 00| ||eng c
024 7 |a 10.1107/S0909049512029640  |2 doi 
028 5 2 |a pubmed24n1344.xml 
035 |a (DE-627)NLM220284741 
035 |a (NLM)22898949 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Vila-Comamala, Joan  |e verfasserin  |4 aut 
245 1 0 |a Zone-doubled Fresnel zone plates for high-resolution hard X-ray full-field transmission microscopy 
264 1 |c 2012 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 10.01.2013 
500 |a Date Revised 24.03.2024 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Full-field transmission X-ray microscopy is a unique non-destructive technique for three-dimensional imaging of specimens at the nanometer scale. Here, the use of zone-doubled Fresnel zone plates to achieve a spatial resolution better than 20 nm in the hard X-ray regime (8-10 keV) is reported. By obtaining a tomographic reconstruction of a Ni/YSZ solid-oxide fuel cell, the feasibility of performing three-dimensional imaging of scientifically relevant samples using such high-spatial-resolution Fresnel zone plates is demonstrated 
650 4 |a Journal Article 
650 4 |a Research Support, U.S. Gov't, Non-P.H.S. 
700 1 |a Pan, Yongsheng  |e verfasserin  |4 aut 
700 1 |a Lombardo, Jeffrey J  |e verfasserin  |4 aut 
700 1 |a Harris, William M  |e verfasserin  |4 aut 
700 1 |a Chiu, Wilson K S  |e verfasserin  |4 aut 
700 1 |a David, Christian  |e verfasserin  |4 aut 
700 1 |a Wang, Yuxin  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 19(2012), Pt 5 vom: 23. Sept., Seite 705-9  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:19  |g year:2012  |g number:Pt 5  |g day:23  |g month:09  |g pages:705-9 
856 4 0 |u http://dx.doi.org/10.1107/S0909049512029640  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 19  |j 2012  |e Pt 5  |b 23  |c 09  |h 705-9