Killing of total heterotrophic bacteria using the gas diffusion electrode system

This study focused on the disinfection of dual electrodes with a gas diffusion cathode using total heterotrophic bacteria as indicator microorganisms. Batch tests were performed to study the effects of platinum load W(Pt) and the pore-forming agent content WNH4HCO3 in gas diffusion electrodes on the...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Environmental technology. - 1998. - 33(2012), 10-12 vom: 16. Juni, Seite 1167-74
1. Verfasser: Xu, W Y (VerfasserIn)
Weitere Verfasser: Li, P
Format: Aufsatz
Sprache:English
Veröffentlicht: 2012
Zugriff auf das übergeordnete Werk:Environmental technology
Schlagworte:Evaluation Study Journal Article Research Support, Non-U.S. Gov't Sulfates sodium sulfate 0YPR65R21J Oxygen S88TT14065
LEADER 01000caa a22002652 4500
001 NLM219926077
003 DE-627
005 20250214071509.0
007 tu
008 231224s2012 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0733.xml 
035 |a (DE-627)NLM219926077 
035 |a (NLM)22856286 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Xu, W Y  |e verfasserin  |4 aut 
245 1 0 |a Killing of total heterotrophic bacteria using the gas diffusion electrode system 
264 1 |c 2012 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 06.09.2012 
500 |a Date Revised 10.12.2019 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a This study focused on the disinfection of dual electrodes with a gas diffusion cathode using total heterotrophic bacteria as indicator microorganisms. Batch tests were performed to study the effects of platinum load W(Pt) and the pore-forming agent content WNH4HCO3 in gas diffusion electrodes on the germicidal efficacy eta and H2O2 yield. The results showed that the disinfection improved with W(Pt), but its efficiency at W(Pt) of 3 per thousand was equivalent to W(Pt) of 4 per thousand. The right amount of the pore-forming agent improved disinfection. Continuous tests were performed to study residence times (RTs), pH and oxygen flow rates Qo2 on the germicidal efficacy and H2O2 yield. The results indicated that at the steady state total heterotrophic bacteria in the outlet stream were completely inactivated under our experimental conditions. Disinfection improved with increasing RT. This phenomenon was more significant when RT < 20 min. A drop in pH value resulted in the rapid rise of germicidal efficacy, while disinfection shortened with an increasing oxygen flow rate Qo2. The operating costs are high. Further research is required to fully understand all parameters and reduce operating costs 
650 4 |a Evaluation Study 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 7 |a Sulfates  |2 NLM 
650 7 |a sodium sulfate  |2 NLM 
650 7 |a 0YPR65R21J  |2 NLM 
650 7 |a Oxygen  |2 NLM 
650 7 |a S88TT14065  |2 NLM 
700 1 |a Li, P  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Environmental technology  |d 1998  |g 33(2012), 10-12 vom: 16. Juni, Seite 1167-74  |w (DE-627)NLM098202545  |x 0959-3330  |7 nnns 
773 1 8 |g volume:33  |g year:2012  |g number:10-12  |g day:16  |g month:06  |g pages:1167-74 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 33  |j 2012  |e 10-12  |b 16  |c 06  |h 1167-74