Study on the removal efficiency of UF membranes using bacteriophages in bench-scale and semi-technical scale

To determine the removal efficiency of ultrafiltration (UF) membranes for nano-particles in the size range of viruses the state of the art uses challenge tests with virus-spiked water. This work focuses on bench-scale and semi-technical scale experiments. Different experimental parameters influencin...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 66(2012), 6 vom: 24., Seite 1195-202
1. Verfasser: Kreissel, K (VerfasserIn)
Weitere Verfasser: Bösl, M, Lipp, P, Franzreb, M, Hambsch, B
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2012
Zugriff auf das übergeordnete Werk:Water science and technology : a journal of the International Association on Water Pollution Research
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Membranes, Artificial
LEADER 01000naa a22002652 4500
001 NLM21969463X
003 DE-627
005 20231224043540.0
007 cr uuu---uuuuu
008 231224s2012 xx |||||o 00| ||eng c
024 7 |a 10.2166/wst.2012.299  |2 doi 
028 5 2 |a pubmed24n0732.xml 
035 |a (DE-627)NLM21969463X 
035 |a (NLM)22828295 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kreissel, K  |e verfasserin  |4 aut 
245 1 0 |a Study on the removal efficiency of UF membranes using bacteriophages in bench-scale and semi-technical scale 
264 1 |c 2012 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 18.10.2012 
500 |a Date Revised 25.07.2012 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a To determine the removal efficiency of ultrafiltration (UF) membranes for nano-particles in the size range of viruses the state of the art uses challenge tests with virus-spiked water. This work focuses on bench-scale and semi-technical scale experiments. Different experimental parameters influencing the removal efficiency of the tested UF membrane modules were analyzed and evaluated for bench- and semi-technical scale experiments. Organic matter in the water matrix highly influenced the removal of the tested bacteriophages MS2 and phiX174. Less membrane fouling (low ΔTMP) led to a reduced phage reduction. Increased flux positively affected phage removal in natural waters. The tested bacteriophages MS2 and phiX174 revealed different removal properties. MS2, which is widely used as a model organism to determine virus removal efficiencies of membranes, mostly showed a better removal than phiX174 for the natural water qualities tested. It seems that MS2 is possibly a less conservative surrogate for human enteric virus removal than phiX174. In bench-scale experiments log removal values (LRV) for MS2 of 2.5-6.0 and of 2.5-4.5 for phiX174 were obtained for the examined range of parameters. Phage removal obtained with differently fabricated semi-technical modules was quite variable for comparable parameter settings, indicating that module fabrication can lead to differing results. Potting temperature and module size were identified as influencing factors. In conclusion, careful attention has to be paid to the choice of experimental settings and module potting when using bench-scale or semi-technical scale experiments for UF membrane challenge tests 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 7 |a Membranes, Artificial  |2 NLM 
700 1 |a Bösl, M  |e verfasserin  |4 aut 
700 1 |a Lipp, P  |e verfasserin  |4 aut 
700 1 |a Franzreb, M  |e verfasserin  |4 aut 
700 1 |a Hambsch, B  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Water science and technology : a journal of the International Association on Water Pollution Research  |d 1986  |g 66(2012), 6 vom: 24., Seite 1195-202  |w (DE-627)NLM098149431  |x 0273-1223  |7 nnns 
773 1 8 |g volume:66  |g year:2012  |g number:6  |g day:24  |g pages:1195-202 
856 4 0 |u http://dx.doi.org/10.2166/wst.2012.299  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 66  |j 2012  |e 6  |b 24  |h 1195-202