The relationship between flow and bacteria in streams

A method is proposed to relate the statistics of in-stream bacteria concentrations to the surface-runoff fraction of stream flow. The parameters of this relationship include the characteristic concentration of bacteria in surface runoff and the characteristic concentration of bacteria in the base fl...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water environment research : a research publication of the Water Environment Federation. - 1998. - 84(2012), 3 vom: 11. März, Seite 227-36
1. Verfasser: Chin, David A (VerfasserIn)
Format: Aufsatz
Sprache:English
Veröffentlicht: 2012
Zugriff auf das übergeordnete Werk:Water environment research : a research publication of the Water Environment Federation
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM219125325
003 DE-627
005 20231224042139.0
007 tu
008 231224s2012 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0730.xml 
035 |a (DE-627)NLM219125325 
035 |a (NLM)22755490 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Chin, David A  |e verfasserin  |4 aut 
245 1 4 |a The relationship between flow and bacteria in streams 
264 1 |c 2012 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 26.07.2012 
500 |a Date Revised 23.09.2019 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a A method is proposed to relate the statistics of in-stream bacteria concentrations to the surface-runoff fraction of stream flow. The parameters of this relationship include the characteristic concentration of bacteria in surface runoff and the characteristic concentration of bacteria in the base flow, and these parameters can be derived from synoptic bacteria and flow measurements. The effectiveness of the proposed method is demonstrated at several U.S. locations for both Escherichia coli and fecal coliform bacteria. Application of the proposed method at a particular location showed that the method can be used to identify the most effective bacteria source controls and that conventional application of the load-duration curve might lead to erroneous identification of target sources 
650 4 |a Journal Article 
773 0 8 |i Enthalten in  |t Water environment research : a research publication of the Water Environment Federation  |d 1998  |g 84(2012), 3 vom: 11. März, Seite 227-36  |w (DE-627)NLM098214292  |x 1554-7531  |7 nnns 
773 1 8 |g volume:84  |g year:2012  |g number:3  |g day:11  |g month:03  |g pages:227-36 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 84  |j 2012  |e 3  |b 11  |c 03  |h 227-36