Use of Cramer-Rao Lower Bound for Performance Evaluation of Different Monolithic Crystal PET Detector Designs

We have previously reported on continuous miniature crystal element (cMiCE) PET detectors that provide depth of interaction (DOI) positioning capability. A key component of the design is the use of a statistics-based positioning (SBP) method for 3D event positioning. The Cramer-Rao lower bound (CRLB...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science. - 1988. - 59(2012), 1 vom: 16., Seite 3-12
1. Verfasser: Li, Xiaoli (VerfasserIn)
Weitere Verfasser: Hunter, William C J, Lewellen, Tom K, Miyaoka, Robert S
Format: Aufsatz
Sprache:English
Veröffentlicht: 2012
Zugriff auf das übergeordnete Werk:IEEE transactions on nuclear science
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM218508999
003 DE-627
005 20250214030353.0
007 tu
008 231224s2012 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0728.xml 
035 |a (DE-627)NLM218508999 
035 |a (NLM)22685349 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Li, Xiaoli  |e verfasserin  |4 aut 
245 1 0 |a Use of Cramer-Rao Lower Bound for Performance Evaluation of Different Monolithic Crystal PET Detector Designs 
264 1 |c 2012 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Revised 10.06.2024 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a We have previously reported on continuous miniature crystal element (cMiCE) PET detectors that provide depth of interaction (DOI) positioning capability. A key component of the design is the use of a statistics-based positioning (SBP) method for 3D event positioning. The Cramer-Rao lower bound (CRLB) expresses limits on the estimate variances for a set of deterministic parameters. We examine the CRLB as a useful metric to evaluate the performance of our SBP algorithm and to quickly compare the best possible resolution when investigating new detector designs.In this work, the CRLB is first reported based upon experimental results from a cMiCE detector using a 50×50×15-mm(3) LYSO crystal readout by a 64-channel PMT (Hamamatsu H8500) on the exit surface of the crystal. The X/Y resolution is relatively close to the CRLB, while the DOI resolution is more than double the CRLB even after correcting for beam diameter and finite X (i.e., reference DOI position) resolution of the detector. The positioning performance of the cMiCE detector with the same design was also evaluated through simulation. Similar with the experimental results, the difference between the CRLB and measured spatial resolution is bigger in DOI direction than in X/Y direction.Another simulation study was conducted to investigate what causes the difference between the measured spatial resolution and the CRLB. The cMiCE detector with novel sensor-on-entrance-surface (SES) design was modeled as a 49.2×49.2×15-mm(3) LYSO crystal readout by a 12×12 array of 3.8×3.8-mm(2) silicon photomultiplier (SiPM) elements with 4.1-mm center-to-center spacing on the entrance surface of the crystal. The results show that there are two main causes to account for the differences between the spatial resolution and the CRLB. First, Compton scatter in the crystal degrades the spatial resolution. The DOI resolution is degraded more than the X/Y resolution since small angle scatter is preferred. Second, our maximum likelihood (ML) clustering algorithm also has limitations when developing 3D look up tables during detector calibration 
650 4 |a Journal Article 
700 1 |a Hunter, William C J  |e verfasserin  |4 aut 
700 1 |a Lewellen, Tom K  |e verfasserin  |4 aut 
700 1 |a Miyaoka, Robert S  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on nuclear science  |d 1988  |g 59(2012), 1 vom: 16., Seite 3-12  |w (DE-627)NLM098149350  |x 0018-9499  |7 nnns 
773 1 8 |g volume:59  |g year:2012  |g number:1  |g day:16  |g pages:3-12 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 59  |j 2012  |e 1  |b 16  |h 3-12