Minimising the risk on phosphorus limitation; an optimised coagulant dosage system

In the near future the WWTP Horstermeer will be confronted with more stringent requirements. Important factor in this respect is the European Water Framework Directive 2000/60/EC. Within the WFD approach the focus is more and more on low nitrogen (<2.2 mg N-total/L) and phosphorus concentrations...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 64(2011), 8 vom: 15., Seite 1708-15
1. Verfasser: Scherrenberg, S M (VerfasserIn)
Weitere Verfasser: Menkveld, H W H, Bechger, M, van der Graaf, J H J M
Format: Aufsatz
Sprache:English
Veröffentlicht: 2011
Zugriff auf das übergeordnete Werk:Water science and technology : a journal of the International Association on Water Pollution Research
Schlagworte:Journal Article Water Pollutants, Chemical Phosphorus 27YLU75U4W Nitrogen N762921K75
Beschreibung
Zusammenfassung:In the near future the WWTP Horstermeer will be confronted with more stringent requirements. Important factor in this respect is the European Water Framework Directive 2000/60/EC. Within the WFD approach the focus is more and more on low nitrogen (<2.2 mg N-total/L) and phosphorus concentrations (<0.15 mg P-total/L) in WWTP effluent. Therefore, research has been initiated at the Horstermeer WWTP to investigate the possibilities of simultaneous nutrient removal with filtration techniques. After nitrite accumulation, caused by phosphorus limitation, was measured in the filtrate water of the 1-STEP filter, research has started. The objective of this research is to minimise the risk on the inhibition of denitrification by phosphorus limitation and to decrease the dosage of coagulant. Therefore a new coagulant dosage system is developed. The back-ground of the coagulant dosage system, the results and cost savings are discussed in this article. When the PO4-P/NOx-N ratio in the WWTP effluent becomes below 0.06 mg/mg phosphorus limitation may occur. The results for phosphorus and nitrogen removal are equal or improved compared to the yearly average of 2008. The results show a more stable removal process and a reduction of the coagulant dosage for the coagulant dosage system of 11% when compared to a continuous dosage ratio of MeP 4 mol/mol
Beschreibung:Date Completed 04.04.2012
Date Revised 18.09.2019
published: Print
Citation Status MEDLINE
ISSN:0273-1223