Application of a generalized scan statistic model to evaluate TOF PET images

Noise equivalent counts (NEC) have been used as a measure or proxy of PET image quality for many years. It has been shown to be a useful metric, for example to determine clinical patient dosage. However, NEC should be used cautiously in evaluating image quality since it is a global data quality meas...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science. - 1988. - 58(2011), 1 vom: 23., Seite 99-104
1. Verfasser: Surti, Suleman (VerfasserIn)
Weitere Verfasser: Karp, Joel S
Format: Aufsatz
Sprache:English
Veröffentlicht: 2011
Zugriff auf das übergeordnete Werk:IEEE transactions on nuclear science
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM213791927
003 DE-627
005 20250213114218.0
007 tu
008 231224s2011 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0712.xml 
035 |a (DE-627)NLM213791927 
035 |a (NLM)22163117 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Surti, Suleman  |e verfasserin  |4 aut 
245 1 0 |a Application of a generalized scan statistic model to evaluate TOF PET images 
264 1 |c 2011 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Revised 21.10.2021 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Noise equivalent counts (NEC) have been used as a measure or proxy of PET image quality for many years. It has been shown to be a useful metric, for example to determine clinical patient dosage. However, NEC should be used cautiously in evaluating image quality since it is a global data quality measure that does not take into account localized effects due to spatial resolution and image reconstruction, as well as the effect of time-of-flight (TOF) imaging on resultant images. In this work, we study the use of a numerical observer that uses a generalized scan-statistic model to estimate lesion detectability with localization in a uniform background phantom, for varying activity levels and scan times. Data were acquired on a clinical whole-body TOF PET scanner. Data show that ALROC increases as a function of NEC but at high activity levels it approaches a peak value earlier than the NEC peak. Also, the ALROC for images acquired with the same NEC, but at two different activity levels and scan times, is similar. Our results show that with TOF information we can either achieve improved clinical performance for heavy patients, or reduce the scan time or injected activity while maintaining similar ALROC value as in a Non-TOF image 
650 4 |a Journal Article 
700 1 |a Karp, Joel S  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on nuclear science  |d 1988  |g 58(2011), 1 vom: 23., Seite 99-104  |w (DE-627)NLM098149350  |x 0018-9499  |7 nnns 
773 1 8 |g volume:58  |g year:2011  |g number:1  |g day:23  |g pages:99-104 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 58  |j 2011  |e 1  |b 23  |h 99-104