|
|
|
|
LEADER |
01000naa a22002652 4500 |
001 |
NLM20928479X |
003 |
DE-627 |
005 |
20231224005512.0 |
007 |
cr uuu---uuuuu |
008 |
231224s2011 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1107/S0909049511011848
|2 doi
|
028 |
5 |
2 |
|a pubmed24n0698.xml
|
035 |
|
|
|a (DE-627)NLM20928479X
|
035 |
|
|
|a (NLM)21685676
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Pauluhn, Anuschka
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Automatic loop centring with a high-precision goniometer head at the SLS macromolecular crystallography beamlines
|
264 |
|
1 |
|c 2011
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 13.10.2011
|
500 |
|
|
|a Date Revised 05.11.2023
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status PubMed-not-MEDLINE
|
520 |
|
|
|a Automatic loop centring has been developed as part of the automation process in crystallographic data collection at the Swiss Light Source. The procedure described here consists of an optional set-up part, in which the background images are taken, and the actual centring part. The algorithm uses boundary and centre-of-mass detection at two different microscope image magnifications. Micromounts can be handled as well. Centring of the loops can be achieved in 15-26s, depending on their initial position, and as fast as manual centring. The alignment of the sample is carried out by means of a new flexural-hinge-based compact goniometer head. The device features an electromagnet for robotic wet mounting of samples. The circle of confusion was measured to be smaller than 1 µm (r.m.s.); its bidirectional backlash is below 2 µm
|
650 |
|
4 |
|a Journal Article
|
700 |
1 |
|
|a Pradervand, Claude
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Rossetti, Daniel
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Salathe, Marco
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Schulze-Briese, Clemens
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Journal of synchrotron radiation
|d 1994
|g 18(2011), Pt 4 vom: 22. Juli, Seite 595-600
|w (DE-627)NLM09824129X
|x 1600-5775
|7 nnns
|
773 |
1 |
8 |
|g volume:18
|g year:2011
|g number:Pt 4
|g day:22
|g month:07
|g pages:595-600
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1107/S0909049511011848
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_40
|
912 |
|
|
|a GBV_ILN_350
|
912 |
|
|
|a GBV_ILN_2005
|
951 |
|
|
|a AR
|
952 |
|
|
|d 18
|j 2011
|e Pt 4
|b 22
|c 07
|h 595-600
|