Protein adsorption on poly(N-isopropylacrylamide) brushes : dependence on grafting density and chain collapse

The protein resistance of poly(N-isopropylacrylamide) brushes grafted from silicon wafers was investigated as a function of the chain molecular weight, grafting density, and temperature. Above the lower critical solution temperature (LCST) of 32 °C, the collapse of the water-swollen chains, determin...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1992. - 27(2011), 14 vom: 19. Juli, Seite 8810-8
1. Verfasser: Xue, Changying (VerfasserIn)
Weitere Verfasser: Yonet-Tanyeri, Nihan, Brouette, Nicolas, Sferrazza, Michele, Braun, Paul V, Leckband, Deborah E
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2011
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article Research Support, N.I.H., Extramural Research Support, U.S. Gov't, Non-P.H.S. Acrylamides Acrylic Resins Polymers Proteins poly-N-isopropylacrylamide 25189-55-3 Silicon Z4152N8IUI
LEADER 01000naa a22002652 4500
001 NLM209064161
003 DE-627
005 20231224005113.0
007 cr uuu---uuuuu
008 231224s2011 xx |||||o 00| ||eng c
024 7 |a 10.1021/la2001909  |2 doi 
028 5 2 |a pubmed24n0697.xml 
035 |a (DE-627)NLM209064161 
035 |a (NLM)21662243 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Xue, Changying  |e verfasserin  |4 aut 
245 1 0 |a Protein adsorption on poly(N-isopropylacrylamide) brushes  |b dependence on grafting density and chain collapse 
264 1 |c 2011 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 03.11.2011 
500 |a Date Revised 20.10.2021 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a The protein resistance of poly(N-isopropylacrylamide) brushes grafted from silicon wafers was investigated as a function of the chain molecular weight, grafting density, and temperature. Above the lower critical solution temperature (LCST) of 32 °C, the collapse of the water-swollen chains, determined by ellipsometry, depends on the grafting density and molecular weight. Ellipsometry, radio assay, and fluorescence imaging demonstrated that, below the lower critical solution temperature, the brushes repel protein as effectively as oligoethylene oxide-terminated monolayers. Above 32 °C, very low levels of protein adsorb on densely grafted brushes, and the amounts of adsorbed protein increase with decreasing brush-grafting-densities. Brushes that do not exhibit a collapse transition also bind protein, even though the chains remain extended above the LCST. These findings suggest possible mechanisms underlying protein interactions with end-grafted poly(N-isopropyl acrylamide) brushes 
650 4 |a Journal Article 
650 4 |a Research Support, N.I.H., Extramural 
650 4 |a Research Support, U.S. Gov't, Non-P.H.S. 
650 7 |a Acrylamides  |2 NLM 
650 7 |a Acrylic Resins  |2 NLM 
650 7 |a Polymers  |2 NLM 
650 7 |a Proteins  |2 NLM 
650 7 |a poly-N-isopropylacrylamide  |2 NLM 
650 7 |a 25189-55-3  |2 NLM 
650 7 |a Silicon  |2 NLM 
650 7 |a Z4152N8IUI  |2 NLM 
700 1 |a Yonet-Tanyeri, Nihan  |e verfasserin  |4 aut 
700 1 |a Brouette, Nicolas  |e verfasserin  |4 aut 
700 1 |a Sferrazza, Michele  |e verfasserin  |4 aut 
700 1 |a Braun, Paul V  |e verfasserin  |4 aut 
700 1 |a Leckband, Deborah E  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1992  |g 27(2011), 14 vom: 19. Juli, Seite 8810-8  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnns 
773 1 8 |g volume:27  |g year:2011  |g number:14  |g day:19  |g month:07  |g pages:8810-8 
856 4 0 |u http://dx.doi.org/10.1021/la2001909  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_350 
912 |a GBV_ILN_721 
951 |a AR 
952 |d 27  |j 2011  |e 14  |b 19  |c 07  |h 8810-8