Reliable measurements of interfacial slip by colloid probe atomic force microscopy. I. Mathematical modeling

We developed a stable spread-sheet algorithm for the calculation of the hydrodynamic forces measured by colloid probe atomic force microscopy to be used in investigations of interfacial slip. The algorithm quantifies the effect on the slip hydrodynamic force for factors commonly encountered in exper...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1992. - 27(2011), 11 vom: 07. Juni, Seite 6701-11
1. Verfasser: Zhu, Liwen (VerfasserIn)
Weitere Verfasser: Attard, Phil, Neto, Chiara
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2011
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM207945993
003 DE-627
005 20231224003114.0
007 cr uuu---uuuuu
008 231224s2011 xx |||||o 00| ||eng c
024 7 |a 10.1021/la2007809  |2 doi 
028 5 2 |a pubmed24n0693.xml 
035 |a (DE-627)NLM207945993 
035 |a (NLM)21542569 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Zhu, Liwen  |e verfasserin  |4 aut 
245 1 0 |a Reliable measurements of interfacial slip by colloid probe atomic force microscopy. I. Mathematical modeling 
264 1 |c 2011 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 23.09.2011 
500 |a Date Revised 31.05.2011 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a We developed a stable spread-sheet algorithm for the calculation of the hydrodynamic forces measured by colloid probe atomic force microscopy to be used in investigations of interfacial slip. The algorithm quantifies the effect on the slip hydrodynamic force for factors commonly encountered in experimental measurements such as nanoparticle contamination, nonconstant drag force due to cantilever bending that varies with different cantilevers, flattening of the microsphere, and calibration at large separations. We found that all of these experimental factors significantly affect the fitted slip length, approximately in the order listed. Our modeling is applied to fit new experimental data reproducibly. Using this new algorithm, it is shown that the fitting of hydrodynamic theories to experimental data is reliable and the fitted slip length is accurate. A "blind test" protocol was developed that produces a reliable estimate of the fitting error in the determination of both the slip length and spring constant. By this blind test, we estimate that our modeling determines the fitted slip length with an average systematic error of 2 nm and the fitted spring constant with a 3% error. Our exact calculation of the drag force may explain previous reports that the fitted slip length depends upon the shape and spring constant of the cantilever used to perform the measurements 
650 4 |a Journal Article 
700 1 |a Attard, Phil  |e verfasserin  |4 aut 
700 1 |a Neto, Chiara  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1992  |g 27(2011), 11 vom: 07. Juni, Seite 6701-11  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnns 
773 1 8 |g volume:27  |g year:2011  |g number:11  |g day:07  |g month:06  |g pages:6701-11 
856 4 0 |u http://dx.doi.org/10.1021/la2007809  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_350 
912 |a GBV_ILN_721 
951 |a AR 
952 |d 27  |j 2011  |e 11  |b 07  |c 06  |h 6701-11