Electrohydrodynamic deposition of polymeric droplets under low-frequency pulsation

Circularly shaped polymeric droplets with diameter of about 20 μm have been intermittently ejected and deposited in an orderly manner on a collector from a syringe needle by means of near-field, electrohydrodynamic reactions using pulsating voltages at around 2.25 kV. The needle has an inner diamete...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1992. - 27(2011), 10 vom: 17. Mai, Seite 6541-8
1. Verfasser: Xu, Lei (VerfasserIn)
Weitere Verfasser: Wang, Xiang, Lei, Tingping, Sun, Daoheng, Lin, Liwei
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2011
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM207603294
003 DE-627
005 20231224002428.0
007 cr uuu---uuuuu
008 231224s2011 xx |||||o 00| ||eng c
024 7 |a 10.1021/la201107j  |2 doi 
028 5 2 |a pubmed24n0692.xml 
035 |a (DE-627)NLM207603294 
035 |a (NLM)21506585 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Xu, Lei  |e verfasserin  |4 aut 
245 1 0 |a Electrohydrodynamic deposition of polymeric droplets under low-frequency pulsation 
264 1 |c 2011 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 30.08.2011 
500 |a Date Revised 10.05.2011 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Circularly shaped polymeric droplets with diameter of about 20 μm have been intermittently ejected and deposited in an orderly manner on a collector from a syringe needle by means of near-field, electrohydrodynamic reactions using pulsating voltages at around 2.25 kV. The needle has an inner diameter of 100 μm and was placed 1 mm above a silicon conductor substrate to have location control for droplet depositions. Under low-frequency operation of less than 100 Hz, the deposition frequency of droplets, f(dep), has been observed to be equal to the frequency of the applied driving voltage divided by an integer, N, as small as 1. Furthermore, the diameter of the deposited droplets has been found to be linearly dependent on (Q/f(dep))(1/3), where Q is the polymer solution supply rate at around 30 nL/s. These experimentally observed droplet ejection rules under low-frequency pulsation provide useful design guidelines for controllable deposition of polymer droplets in various potential applications, including electrohydrodynamic printing 
650 4 |a Journal Article 
700 1 |a Wang, Xiang  |e verfasserin  |4 aut 
700 1 |a Lei, Tingping  |e verfasserin  |4 aut 
700 1 |a Sun, Daoheng  |e verfasserin  |4 aut 
700 1 |a Lin, Liwei  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1992  |g 27(2011), 10 vom: 17. Mai, Seite 6541-8  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnns 
773 1 8 |g volume:27  |g year:2011  |g number:10  |g day:17  |g month:05  |g pages:6541-8 
856 4 0 |u http://dx.doi.org/10.1021/la201107j  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_350 
912 |a GBV_ILN_721 
951 |a AR 
952 |d 27  |j 2011  |e 10  |b 17  |c 05  |h 6541-8