Direct and quantitative comparison of pixelated density profiles with high-resolution X-ray reflectivity data

A method for comparing pixelated density profiles (e.g. obtained from molecular dynamics or other computational techniques) with experimental X-ray reflectivity data both directly and quantitatively is described. The conditions under which such a comparison can be made quantitatively (e.g. with erro...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 18(2011), Pt 2 vom: 21. März, Seite 257-65
1. Verfasser: Fenter, P (VerfasserIn)
Weitere Verfasser: Lee, S S, Skelton, A A, Cummings, P T
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2011
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Water 059QF0KO0R Quartz 14808-60-7
LEADER 01000caa a22002652 4500
001 NLM206004699
003 DE-627
005 20250212114413.0
007 cr uuu---uuuuu
008 231223s2011 xx |||||o 00| ||eng c
024 7 |a 10.1107/S0909049510040422  |2 doi 
028 5 2 |a pubmed25n0687.xml 
035 |a (DE-627)NLM206004699 
035 |a (NLM)21335914 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Fenter, P  |e verfasserin  |4 aut 
245 1 0 |a Direct and quantitative comparison of pixelated density profiles with high-resolution X-ray reflectivity data 
264 1 |c 2011 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 03.06.2011 
500 |a Date Revised 21.11.2013 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a A method for comparing pixelated density profiles (e.g. obtained from molecular dynamics or other computational techniques) with experimental X-ray reflectivity data both directly and quantitatively is described. The conditions under which such a comparison can be made quantitatively (e.g. with errors <1%) are determined theoretically by comparing calculated structure factors for an intrinsic continuous density profile with those obtained from density profiles that have been binned into regular spatial increments. The accuracy of the X-ray reflectivity calculations for binned density profiles is defined in terms of the inter-relationships between resolution of the X-ray reflectivity data (i.e. its range in momentum transfer), the chosen bin size and the width of the intrinsic density profile. These factors play a similar role in the application of any structure-factor calculations that involve the use of pixelated density profiles, such as those obtained from iterative phasing algorithms for inverting structures from X-ray reflectivity and coherent diffraction imaging data. Finally, it is shown how simulations of a quartz-water interface can be embedded into an exact description of the `bulk' phases (including the substrate crystal and the fluid water, below and above the actual interface) to quantitatively reproduce the experimental reflectivity data of a solid-liquid interface 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 7 |a Water  |2 NLM 
650 7 |a 059QF0KO0R  |2 NLM 
650 7 |a Quartz  |2 NLM 
650 7 |a 14808-60-7  |2 NLM 
700 1 |a Lee, S S  |e verfasserin  |4 aut 
700 1 |a Skelton, A A  |e verfasserin  |4 aut 
700 1 |a Cummings, P T  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 18(2011), Pt 2 vom: 21. März, Seite 257-65  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:18  |g year:2011  |g number:Pt 2  |g day:21  |g month:03  |g pages:257-65 
856 4 0 |u http://dx.doi.org/10.1107/S0909049510040422  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 18  |j 2011  |e Pt 2  |b 21  |c 03  |h 257-65