Time-resolved photoelectron spectroscopy using synchrotron radiation time structure

Synchrotron radiation time structure is becoming a common tool for studying dynamic properties of materials. The main limitation is often the wide time domain the user would like to access with pump-probe experiments. In order to perform photoelectron spectroscopy experiments over time scales from m...

Description complète

Détails bibliographiques
Publié dans:Journal of synchrotron radiation. - 1994. - 18(2011), Pt 2 vom: 21. März, Seite 245-50
Auteur principal: Bergeard, N (Auteur)
Autres auteurs: Silly, M G, Krizmancic, D, Chauvet, C, Guzzo, M, Ricaud, J P, Izquierdo, M, Stebel, L, Pittana, P, Sergo, R, Cautero, G, Dufour, G, Rochet, F, Sirotti, F
Format: Article en ligne
Langue:English
Publié: 2011
Accès à la collection:Journal of synchrotron radiation
Sujets:Journal Article Research Support, Non-U.S. Gov't
Description
Résumé:Synchrotron radiation time structure is becoming a common tool for studying dynamic properties of materials. The main limitation is often the wide time domain the user would like to access with pump-probe experiments. In order to perform photoelectron spectroscopy experiments over time scales from milliseconds to picoseconds it is mandatory to measure the time at which each measured photoelectron was created. For this reason the usual CCD camera-based two-dimensional detection of electron energy analyzers has been replaced by a new delay-line detector adapted to the time structure of the SOLEIL synchrotron radiation source. The new two-dimensional delay-line detector has a time resolution of 5 ns and was installed on a Scienta SES 2002 electron energy analyzer. The first application has been to characterize the time of flight of the photoemitted electrons as a function of their kinetic energy and the selected pass energy. By repeating the experiment as a function of the available pass energy and of the kinetic energy, a complete characterization of the analyzer behaviour in the time domain has been obtained. Even for kinetic energies as low as 10 eV at 2 eV pass energy, the time spread of the detected electrons is lower than 140 ns. These results and the time structure of the SOLEIL filling modes assure the possibility of performing pump-probe photoelectron spectroscopy experiments with the time resolution given by the SOLEIL pulse width, the best performance of the beamline and of the experimental station
Description:Date Completed 03.06.2011
Date Revised 21.02.2011
published: Print-Electronic
Citation Status PubMed-not-MEDLINE
ISSN:1600-5775