3-D reconstruction of microtubules from multi-angle total internal reflection fluorescence microscopy using Bayesian framework

Total internal reflection fluorescence (TIRF) microscopy excites a thin evanescent field which theoretically decays exponentially. Each TIRF image is actually the projection of a 3-D volume and hence cannot alone produce an accurate localization of structures in the z-dimension, however, it provides...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on image processing : a publication of the IEEE Signal Processing Society. - 1992. - 20(2011), 8 vom: 15. Aug., Seite 2248-59
1. Verfasser: Yang, Qian (VerfasserIn)
Weitere Verfasser: Karpikov, Alexander, Toomre, Derek, Duncan, James S
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2011
Zugriff auf das übergeordnete Werk:IEEE transactions on image processing : a publication of the IEEE Signal Processing Society
Schlagworte:Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't
LEADER 01000naa a22002652 4500
001 NLM205898637
003 DE-627
005 20231223234823.0
007 cr uuu---uuuuu
008 231223s2011 xx |||||o 00| ||eng c
024 7 |a 10.1109/TIP.2011.2114359  |2 doi 
028 5 2 |a pubmed24n0686.xml 
035 |a (DE-627)NLM205898637 
035 |a (NLM)21324778 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Yang, Qian  |e verfasserin  |4 aut 
245 1 0 |a 3-D reconstruction of microtubules from multi-angle total internal reflection fluorescence microscopy using Bayesian framework 
264 1 |c 2011 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 07.11.2011 
500 |a Date Revised 19.07.2011 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a Total internal reflection fluorescence (TIRF) microscopy excites a thin evanescent field which theoretically decays exponentially. Each TIRF image is actually the projection of a 3-D volume and hence cannot alone produce an accurate localization of structures in the z-dimension, however, it provides greatly improved axial resolution for biological samples. Multiple angle-TIRF microscopy allows controlled variation of the incident angle of the illuminating laser beam, thus generating a set of images of different penetration depths with the potential to reconstruct the 3-D volume of the sample. With the ultimate goal to quantify important biological parameters of microtubules, we present a method to reconstruct 3-D position and orientation of microtubules based on multi-angle TIRF data, as well as experimental calibration of the actual decay function of the evanescent field at each angle. We validate our method using computer simulations, by creating a phantom simulating the curvilinear characteristics of microtubules and project the artificially constructed volume into a set of TIRF image for different penetration depth. The reconstructed depth information for the phantom data is shown to be accurate and robust to noise. We apply our method to microtubule TIRF images of PtK(2) cells in vivo. By comparing microtubule curvatures of the reconstruction results and several electron microscopy (EM) images of vertically sliced sample of microtubules, we find that the curvature statistics of our reconstruction agree well with the ground truth (EM data). Quantifying the distribution of microtubule curvature reveals an interesting discovery that microtubules can buckle and form local bendings of considerably small radius of curvature which is also visually spotted on the EM images, while microtubule bendings on a larger scale generally have a much larger radius and cannot bear the stress of a large curvature. The presented method has the potential to provide a reliable tool for 3-D reconstruction and tracking of microtubules 
650 4 |a Journal Article 
650 4 |a Research Support, N.I.H., Extramural 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Karpikov, Alexander  |e verfasserin  |4 aut 
700 1 |a Toomre, Derek  |e verfasserin  |4 aut 
700 1 |a Duncan, James S  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on image processing : a publication of the IEEE Signal Processing Society  |d 1992  |g 20(2011), 8 vom: 15. Aug., Seite 2248-59  |w (DE-627)NLM09821456X  |x 1941-0042  |7 nnns 
773 1 8 |g volume:20  |g year:2011  |g number:8  |g day:15  |g month:08  |g pages:2248-59 
856 4 0 |u http://dx.doi.org/10.1109/TIP.2011.2114359  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 20  |j 2011  |e 8  |b 15  |c 08  |h 2248-59