Alignment of plate-like particles in a colloidal dispersion under flow in a uniform pipe studied by high-energy X-ray diffraction

High-energy angle-dispersive X-ray diffraction has been used to study the alignment of colloidal suspension of kaolinite particles in water as they flow along a pipe. X-rays with energies above 25 keV have a major advantage, as they can penetrate through thick samples and walls of containers and per...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1992. - 26(2010), 24 vom: 21. Dez., Seite 18701-9
1. Verfasser: Qazi, S Junaid S (VerfasserIn)
Weitere Verfasser: Rennie, Adrian R, Wright, Jonathan P, Cockcroft, Jeremy K
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2010
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM203748417
003 DE-627
005 20231223230720.0
007 cr uuu---uuuuu
008 231223s2010 xx |||||o 00| ||eng c
024 7 |a 10.1021/la103537y  |2 doi 
028 5 2 |a pubmed24n0679.xml 
035 |a (DE-627)NLM203748417 
035 |a (NLM)21090750 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Qazi, S Junaid S  |e verfasserin  |4 aut 
245 1 0 |a Alignment of plate-like particles in a colloidal dispersion under flow in a uniform pipe studied by high-energy X-ray diffraction 
264 1 |c 2010 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 17.03.2011 
500 |a Date Revised 14.12.2010 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a High-energy angle-dispersive X-ray diffraction has been used to study the alignment of colloidal suspension of kaolinite particles in water as they flow along a pipe. X-rays with energies above 25 keV have a major advantage, as they can penetrate through thick samples and walls of containers and permit investigation of samples under realistic flow conditions. As an example of the method, flow through a circular cross-section pipe with an internal diameter of 5 mm has been studied: this is typical of industrial applications. The angular distribution of intensities of peaks in the diffraction pattern as a function of the location of the pipe in the X-ray beam provides information about the alignment of particles under flow. Order parameters have been calculated to describe the alignment and direction of orientation. It is observed that the particles align in the direction of flow with their flat faces parallel to the flow. The experimental results are compared with the calculations of the local strain rate that help to explain the onset of alignment of the particles 
650 4 |a Journal Article 
700 1 |a Rennie, Adrian R  |e verfasserin  |4 aut 
700 1 |a Wright, Jonathan P  |e verfasserin  |4 aut 
700 1 |a Cockcroft, Jeremy K  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1992  |g 26(2010), 24 vom: 21. Dez., Seite 18701-9  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnns 
773 1 8 |g volume:26  |g year:2010  |g number:24  |g day:21  |g month:12  |g pages:18701-9 
856 4 0 |u http://dx.doi.org/10.1021/la103537y  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_350 
912 |a GBV_ILN_721 
951 |a AR 
952 |d 26  |j 2010  |e 24  |b 21  |c 12  |h 18701-9