Membrane foulants and fouling mechanisms in microfiltration and ultrafiltration of an activated sludge effluent

Membrane fouling in microfiltration (MF) and ultrafiltration (UF) of an activated sludge (AS) effluent was investigated. It was found that the major membrane foulants were polysaccharides, proteins, polysaccharide-like and protein-like materials and humic substances. MF fouling by the raw effluent w...

Description complète

Détails bibliographiques
Publié dans:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 62(2010), 9 vom: 01., Seite 1975-83
Auteur principal: Nguyen, S T (Auteur)
Autres auteurs: Roddick, F A, Harris, J L
Format: Article en ligne
Langue:English
Publié: 2010
Accès à la collection:Water science and technology : a journal of the International Association on Water Pollution Research
Sujets:Journal Article Research Support, Non-U.S. Gov't Membranes, Artificial Sewage