Ratio-contrast imaging of dual-energy absorption for element mapping with a scanning transmission X-ray microscope

The detection of chemical mapping with a spatial resolution of 30 nm has been achieved with a scanning transmission X-ray microscope at the Shanghai Synchrotron Radiation Facility. For each specimen, two absorption images were scanned separately with energies E(1) and E(2): E(1) was focused on the a...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 17(2010), 6 vom: 19. Nov., Seite 804-9
1. Verfasser: Zhang, X Z (VerfasserIn)
Weitere Verfasser: Xu, Z J, Tai, R Z, Zhen, X J, Wang, Y, Guo, Z, Yan, R, Chang, R, Wang, B, Li, M, Zhao, J, Gao, F
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2010
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM202635376
003 DE-627
005 20231223224702.0
007 cr uuu---uuuuu
008 231223s2010 xx |||||o 00| ||eng c
024 7 |a 10.1107/S0909049510031250  |2 doi 
028 5 2 |a pubmed24n0675.xml 
035 |a (DE-627)NLM202635376 
035 |a (NLM)20975228 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Zhang, X Z  |e verfasserin  |4 aut 
245 1 0 |a Ratio-contrast imaging of dual-energy absorption for element mapping with a scanning transmission X-ray microscope 
264 1 |c 2010 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 07.02.2011 
500 |a Date Revised 26.10.2010 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a The detection of chemical mapping with a spatial resolution of 30 nm has been achieved with a scanning transmission X-ray microscope at the Shanghai Synchrotron Radiation Facility. For each specimen, two absorption images were scanned separately with energies E(1) and E(2): E(1) was focused on the absorption edge of the chosen element and E(2) was focused below the edge. A K-edge division method is proposed and applied to obtain the element mapping. Compared with the frequently used K-edge subtraction method, this ratio-contrast method is shown to be more accurate and sensitive in identifying the elements of interest, where the definition of the contrast threshold is simple and clear in physics. Several examples are presented to illustrate the effectiveness of the method 
650 4 |a Journal Article 
700 1 |a Xu, Z J  |e verfasserin  |4 aut 
700 1 |a Tai, R Z  |e verfasserin  |4 aut 
700 1 |a Zhen, X J  |e verfasserin  |4 aut 
700 1 |a Wang, Y  |e verfasserin  |4 aut 
700 1 |a Guo, Z  |e verfasserin  |4 aut 
700 1 |a Yan, R  |e verfasserin  |4 aut 
700 1 |a Chang, R  |e verfasserin  |4 aut 
700 1 |a Wang, B  |e verfasserin  |4 aut 
700 1 |a Li, M  |e verfasserin  |4 aut 
700 1 |a Zhao, J  |e verfasserin  |4 aut 
700 1 |a Gao, F  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 17(2010), 6 vom: 19. Nov., Seite 804-9  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:17  |g year:2010  |g number:6  |g day:19  |g month:11  |g pages:804-9 
856 4 0 |u http://dx.doi.org/10.1107/S0909049510031250  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 17  |j 2010  |e 6  |b 19  |c 11  |h 804-9