Optimizing the accuracy and precision of the single-pulse Laue technique for synchrotron photo-crystallography

The accuracy that can be achieved in single-pulse pump-probe Laue experiments is discussed. It is shown that with careful tuning of the experimental conditions a reproducibility of the intensity ratios of equivalent intensities obtained in different measurements of 3-4% can be achieved. The single-p...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 17(2010), 4 vom: 02. Juli, Seite 479-85
1. Verfasser: Kamiński, Radosław (VerfasserIn)
Weitere Verfasser: Graber, Timothy, Benedict, Jason B, Henning, Robert, Chen, Yu Sheng, Scheins, Stephan, Messerschmidt, Marc, Coppens, Philip
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2010
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, Non-P.H.S. Iodides Copper 789U1901C5 cuprous iodide 7DE9CA6IL2
LEADER 01000naa a22002652 4500
001 NLM199000263
003 DE-627
005 20231223213806.0
007 cr uuu---uuuuu
008 231223s2010 xx |||||o 00| ||eng c
024 7 |a 10.1107/S0909049510019710  |2 doi 
028 5 2 |a pubmed24n0663.xml 
035 |a (DE-627)NLM199000263 
035 |a (NLM)20567080 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kamiński, Radosław  |e verfasserin  |4 aut 
245 1 0 |a Optimizing the accuracy and precision of the single-pulse Laue technique for synchrotron photo-crystallography 
264 1 |c 2010 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 27.09.2010 
500 |a Date Revised 20.10.2021 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a The accuracy that can be achieved in single-pulse pump-probe Laue experiments is discussed. It is shown that with careful tuning of the experimental conditions a reproducibility of the intensity ratios of equivalent intensities obtained in different measurements of 3-4% can be achieved. The single-pulse experiments maximize the time resolution that can be achieved and, unlike stroboscopic techniques in which the pump-probe cycle is rapidly repeated, minimize the temperature increase due to the laser exposure of the sample 
650 4 |a Journal Article 
650 4 |a Research Support, N.I.H., Extramural 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a Research Support, U.S. Gov't, Non-P.H.S. 
650 7 |a Iodides  |2 NLM 
650 7 |a Copper  |2 NLM 
650 7 |a 789U1901C5  |2 NLM 
650 7 |a cuprous iodide  |2 NLM 
650 7 |a 7DE9CA6IL2  |2 NLM 
700 1 |a Graber, Timothy  |e verfasserin  |4 aut 
700 1 |a Benedict, Jason B  |e verfasserin  |4 aut 
700 1 |a Henning, Robert  |e verfasserin  |4 aut 
700 1 |a Chen, Yu Sheng  |e verfasserin  |4 aut 
700 1 |a Scheins, Stephan  |e verfasserin  |4 aut 
700 1 |a Messerschmidt, Marc  |e verfasserin  |4 aut 
700 1 |a Coppens, Philip  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 17(2010), 4 vom: 02. Juli, Seite 479-85  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:17  |g year:2010  |g number:4  |g day:02  |g month:07  |g pages:479-85 
856 4 0 |u http://dx.doi.org/10.1107/S0909049510019710  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 17  |j 2010  |e 4  |b 02  |c 07  |h 479-85