Diamond X-ray beam-position monitoring using signal readout at the synchrotron radiofrequency

Single-crystal diamond is a material with great potential for the fabrication of X-ray photon beam-position monitors with submicrometre spatial resolution. Low X-ray absorption combined with radiation hardness and excellent thermal-mechanical properties make possible beam-transmissive diamond device...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 17(2010), 4 vom: 02. Juli, Seite 456-64
1. Verfasser: Morse, J (VerfasserIn)
Weitere Verfasser: Solar, B, Graafsma, H
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2010
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't
LEADER 01000naa a22002652 4500
001 NLM199000239
003 DE-627
005 20231223213806.0
007 cr uuu---uuuuu
008 231223s2010 xx |||||o 00| ||eng c
024 7 |a 10.1107/S0909049510016547  |2 doi 
028 5 2 |a pubmed24n0663.xml 
035 |a (DE-627)NLM199000239 
035 |a (NLM)20567077 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Morse, J  |e verfasserin  |4 aut 
245 1 0 |a Diamond X-ray beam-position monitoring using signal readout at the synchrotron radiofrequency 
264 1 |c 2010 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 27.09.2010 
500 |a Date Revised 01.10.2010 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Single-crystal diamond is a material with great potential for the fabrication of X-ray photon beam-position monitors with submicrometre spatial resolution. Low X-ray absorption combined with radiation hardness and excellent thermal-mechanical properties make possible beam-transmissive diamond devices for monitoring synchrotron and free-electron laser X-ray beams. Tests were made using a white bending-magnet synchrotron X-ray beam at DESY to investigate the performance of a position-sensitive diamond device using radiofrequency readout electronics. The device uniformity and position response were measured in a 25 microm collimated X-ray beam with an I-Tech Libera ;Brilliance' system. This readout system was designed for position measurement and feedback control of the electron beam in the synchrotron storage ring, but, as shown here, it can also be used for accurate position readout of a quadrant-electrode single-crystal diamond sensor. The centre-of-gravity position of the F4 X-ray beam at the DORIS III synchrotron was measured with the diamond signal output digitally sampled at a rate of 130 Msample s(-1) by the Brilliance system. Narrow-band filtering and digital averaging of the position signals resulted in a measured position noise below 50 nm (r.m.s.) for a 10 Hz bandwidth 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Solar, B  |e verfasserin  |4 aut 
700 1 |a Graafsma, H  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 17(2010), 4 vom: 02. Juli, Seite 456-64  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:17  |g year:2010  |g number:4  |g day:02  |g month:07  |g pages:456-64 
856 4 0 |u http://dx.doi.org/10.1107/S0909049510016547  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 17  |j 2010  |e 4  |b 02  |c 07  |h 456-64