Three-dimensional synthetic aperture focusing using a rocking convex array transducer

Volumetric imaging can be performed using 1-D arrays in combination with mechanical motion. Outside the elevation focus of the array, the resolution and contrast quickly degrade compared with the lateral plane, because of the fixed transducer focus. This paper shows the feasibility of using syntheti...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 57(2010), 5 vom: 30. Mai, Seite 1051-63
1. Verfasser: Andresen, Henrik (VerfasserIn)
Weitere Verfasser: Nikolov, Svetoslav Ivanov, Pedersen, Mads Møller, Buckton, Daniel, Jensen, Jørgen Arendt
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2010
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article Research Support, Non-U.S. Gov't
LEADER 01000naa a22002652 4500
001 NLM197823238
003 DE-627
005 20231223211414.0
007 cr uuu---uuuuu
008 231223s2010 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2010.1517  |2 doi 
028 5 2 |a pubmed24n0659.xml 
035 |a (DE-627)NLM197823238 
035 |a (NLM)20442016 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Andresen, Henrik  |e verfasserin  |4 aut 
245 1 0 |a Three-dimensional synthetic aperture focusing using a rocking convex array transducer 
264 1 |c 2010 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 11.08.2010 
500 |a Date Revised 25.11.2016 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Volumetric imaging can be performed using 1-D arrays in combination with mechanical motion. Outside the elevation focus of the array, the resolution and contrast quickly degrade compared with the lateral plane, because of the fixed transducer focus. This paper shows the feasibility of using synthetic aperture focusing for enhancing the elevation focus for a convex rocking array. The method uses a virtual source (VS) for defocused multi-element transmit, and another VS in the elevation focus point. This allows a direct time-of-flight to be calculated for a given 3-D point. To avoid artifacts and increase SNR at the elevation VS, a plane-wave VS approach has been implemented. Simulations and measurements using an experimental scanner with a convex rocking array show an average improvement in resolution of 26% and 33%, respectively. This improvement is also seen in in vivo measurements. An evaluation of how a change in transducer design will affect the resolution improvement shows a potential for using a modified transducer for 3-D imaging with improved elevation focusing and contrast 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Nikolov, Svetoslav Ivanov  |e verfasserin  |4 aut 
700 1 |a Pedersen, Mads Møller  |e verfasserin  |4 aut 
700 1 |a Buckton, Daniel  |e verfasserin  |4 aut 
700 1 |a Jensen, Jørgen Arendt  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 57(2010), 5 vom: 30. Mai, Seite 1051-63  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:57  |g year:2010  |g number:5  |g day:30  |g month:05  |g pages:1051-63 