X-ray magnetic circular dichroism measurements using an X-ray phase retarder on the BM25 A-SpLine beamline at the ESRF

Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism (XMCD) on the bending-magnet beamline BM25A (SpLine) at the ESRF. Field reversal and helicity reversal tech...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 17(2010), 3 vom: 14. Mai, Seite 308-13
1. Verfasser: Boada, Roberto (VerfasserIn)
Weitere Verfasser: Laguna-Marco, María Angeles, Gallastegui, Jon Ander, Castro, Germán R, Chaboy, Jesús
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2010
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000caa a22002652c 4500
001 NLM197432271
003 DE-627
005 20250211114738.0
007 cr uuu---uuuuu
008 231223s2010 xx |||||o 00| ||eng c
024 7 |a 10.1107/S0909049510005881  |2 doi 
028 5 2 |a pubmed25n0658.xml 
035 |a (DE-627)NLM197432271 
035 |a (NLM)20400827 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Boada, Roberto  |e verfasserin  |4 aut 
245 1 0 |a X-ray magnetic circular dichroism measurements using an X-ray phase retarder on the BM25 A-SpLine beamline at the ESRF 
264 1 |c 2010 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 26.07.2010 
500 |a Date Revised 20.10.2021 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism (XMCD) on the bending-magnet beamline BM25A (SpLine) at the ESRF. Field reversal and helicity reversal techniques have been used to carry out the measurements. The performance of the experimental set-up has been demonstrated by recording XMCD in the energy range from 7 to 11 keV 
650 4 |a Journal Article 
700 1 |a Laguna-Marco, María Angeles  |e verfasserin  |4 aut 
700 1 |a Gallastegui, Jon Ander  |e verfasserin  |4 aut 
700 1 |a Castro, Germán R  |e verfasserin  |4 aut 
700 1 |a Chaboy, Jesús  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 17(2010), 3 vom: 14. Mai, Seite 308-13  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnas 
773 1 8 |g volume:17  |g year:2010  |g number:3  |g day:14  |g month:05  |g pages:308-13 
856 4 0 |u http://dx.doi.org/10.1107/S0909049510005881  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 