|
|
|
|
LEADER |
01000caa a22002652 4500 |
001 |
NLM197219489 |
003 |
DE-627 |
005 |
20250211110929.0 |
007 |
cr uuu---uuuuu |
008 |
231223s2010 xx |||||o 00| ||eng c |
024 |
7 |
|
|a 10.1109/TUFFC.2010.1492
|2 doi
|
028 |
5 |
2 |
|a pubmed25n0657.xml
|
035 |
|
|
|a (DE-627)NLM197219489
|
035 |
|
|
|a (NLM)20378450
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Seo, Joonho
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Three-dimensional computer-controlled acoustic pressure scanning and quantification of focused ultrasound
|
264 |
|
1 |
|c 2010
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
500 |
|
|
|a Date Completed 28.06.2010
|
500 |
|
|
|a Date Revised 09.04.2010
|
500 |
|
|
|a published: Print
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a We propose an automated needle hydrophone-based scanning system to measure high-resolution 3-D acoustic pressure distributions generated by high-intensity focused ultrasound (HIFU). The hardware consists of a host computer, subsystems for HIFU generation, and an oscilloscope to sample the pressure response from a sensor in a water tank. Software was developed to control the hardware subsystems, to search for the initial scan position, and to design the scanning path and volume. A preoperative scanning plan with three perpendicular planes is used to manipulate the position of the HIFU transducer and to automate the acquisition of the spatial acoustic pressure distribution. The post-processing process displays the scanning results, compensates time delays caused by continuous linear scans, and quantifies the focal region. A method to minimize the displacement error induced by the time delay improves the scanning speed of a conventional needle hydrophone-based scanning system. Moreover, a noise-robust, automatic-focus searching algorithm using Gaussian function fitting reduces the total number of iterations and prevents the initial scanning position search from diverging. Finally, the minimum-volume enclosing ellipsoid approximation is used to quantify the size and orientation of the 3-D focal region thresholded by the minimum pressure of interest for various input conditions and to test the reproducibility of the scanning system
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a Research Support, Non-U.S. Gov't
|
700 |
1 |
|
|a Koizumi, Norihiro
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Yoshinaka, Kiyoshi
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Sugita, Naohikoa
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Nomiya, Akira
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Homma, Yukio
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Matsumoto, Yoichiro
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Mitsuishi, Mamoru
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t IEEE transactions on ultrasonics, ferroelectrics, and frequency control
|d 1986
|g 57(2010), 4 vom: 15. Apr., Seite 883-91
|w (DE-627)NLM098181017
|x 1525-8955
|7 nnns
|
773 |
1 |
8 |
|g volume:57
|g year:2010
|g number:4
|g day:15
|g month:04
|g pages:883-91
|
856 |
4 |
0 |
|u http://dx.doi.org/10.1109/TUFFC.2010.1492
|3 Volltext
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_22
|
912 |
|
|
|a GBV_ILN_24
|
912 |
|
|
|a GBV_ILN_350
|
951 |
|
|
|a AR
|
952 |
|
|
|d 57
|j 2010
|e 4
|b 15
|c 04
|h 883-91
|