Designs of a miniaturized sapphire-loaded cavity for spaceborne hydrogen masers

The previous compact hydrogen maser with sapphire microwave cavity at the Beijing Institute of Radio Metrology and Measurement was not suitable for a space application in navigation systems with limitations on volume and weight. To resolve this problem, we present a new design of the sapphire-loaded...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 57(2010), 3 vom: 01. März, Seite 587-91
1. Verfasser: Yang, Ren-fu (VerfasserIn)
Weitere Verfasser: Zhou, Tie-zhong, Wang, Nuan-rang, Gao, Lian-shan
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2010
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article
LEADER 01000caa a22002652c 4500
001 NLM195627067
003 DE-627
005 20250211081319.0
007 cr uuu---uuuuu
008 231223s2010 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2010.1451  |2 doi 
028 5 2 |a pubmed25n0652.xml 
035 |a (DE-627)NLM195627067 
035 |a (NLM)20211774 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Yang, Ren-fu  |e verfasserin  |4 aut 
245 1 0 |a Designs of a miniaturized sapphire-loaded cavity for spaceborne hydrogen masers 
264 1 |c 2010 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 18.06.2010 
500 |a Date Revised 09.03.2010 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a The previous compact hydrogen maser with sapphire microwave cavity at the Beijing Institute of Radio Metrology and Measurement was not suitable for a space application in navigation systems with limitations on volume and weight. To resolve this problem, we present a new design of the sapphire-loaded cavity with optimal parameters in the minimization of volume and maximization of the quality factor. Methods of theoretical calculations, finite element simulation, and related experiments were performed in designing the sapphire-loaded cavity. Based on the analysis, a miniaturized sapphire microwave cavity with the total volume of 3.04 dm(3), the quality factor 67,500, and frequency-temperature coefficient -59.7 kHz/degrees C is developed. The experimental results are completely consistent with calculation values. In addition, the theoretical calculation result shows that the product of the z-component of the magnetic energy filling factor in the bulb region and the cavity TE011-mode Q-factor is 40,800 at 50 degrees C in the miniaturized sapphire cavity. In addition, 2 sapphire-loaded cavities in the Japanese National Institute of Information and Communications Technology and in the Microwave and Optical Communication Research Institute at the University of Limoges, France, are compared with that of our designs 
650 4 |a Journal Article 
700 1 |a Zhou, Tie-zhong  |e verfasserin  |4 aut 
700 1 |a Wang, Nuan-rang  |e verfasserin  |4 aut 
700 1 |a Gao, Lian-shan  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 57(2010), 3 vom: 01. März, Seite 587-91  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnas 
773 1 8 |g volume:57  |g year:2010  |g number:3  |g day:01  |g month:03  |g pages:587-91 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2010.1451  |3 Volltext 