Simultaneous determination of acoustic velocity and density of a cortical bone slab : ultrasonic model-based approach

An ultrasonic setup coupled to a 1-D mathematical model of wave propagation is used to determine the material properties of elastic solids. A maximum likelihood fit of the acoustic response with the model response in the frequency domain enables the simultaneous determination of acoustic velocity, m...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 57(2010), 2 vom: 15., Seite 496-500
1. Verfasser: Longo, R (VerfasserIn)
Weitere Verfasser: Grimal, Q, Laugier, P, Vanlanduit, S, Guillaume, P
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2010
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Letter
LEADER 01000naa a22002652 4500
001 NLM195315081
003 DE-627
005 20231223202530.0
007 cr uuu---uuuuu
008 231223s2010 xx |||||o 00| ||eng c
024 7 |a 10.1109/TUFFC.2010.1430  |2 doi 
028 5 2 |a pubmed24n0651.xml 
035 |a (DE-627)NLM195315081 
035 |a (NLM)20178916 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Longo, R  |e verfasserin  |4 aut 
245 1 0 |a Simultaneous determination of acoustic velocity and density of a cortical bone slab  |b ultrasonic model-based approach 
264 1 |c 2010 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 25.05.2010 
500 |a Date Revised 25.11.2016 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a An ultrasonic setup coupled to a 1-D mathematical model of wave propagation is used to determine the material properties of elastic solids. A maximum likelihood fit of the acoustic response with the model response in the frequency domain enables the simultaneous determination of acoustic velocity, mass density, damping, and sample thickness. The method, previously tested with homogeneous materials, has been applied to compact bone despite the fact that it is a highly attenuating material 
650 4 |a Letter 
700 1 |a Grimal, Q  |e verfasserin  |4 aut 
700 1 |a Laugier, P  |e verfasserin  |4 aut 
700 1 |a Vanlanduit, S  |e verfasserin  |4 aut 
700 1 |a Guillaume, P  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 57(2010), 2 vom: 15., Seite 496-500  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:57  |g year:2010  |g number:2  |g day:15  |g pages:496-500 
856 4 0 |u http://dx.doi.org/10.1109/TUFFC.2010.1430  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 57  |j 2010  |e 2  |b 15  |h 496-500